Diagnostic Error Code FRU/Action
080-000-XXX
Game Port interface Test Passed
1. No action
080-XXX-XXX
Game Port interface Error
1. Remove the game port device and
re-test the system
080-195-XXX
Game Port interface Test aborted by user
1. Information
2. Re-start the test, if necessary
080-196-XXX
Game Port interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
080-197-XXX
Game Port interface test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
080-198-XXX
Game Port interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Go to “Undetermined problems” on page
89
080-199-XXX
Game Port interface test failed, cause
unknown
1. Go to “Undetermined problems” on page
89
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Replace component under function test
086-000-XXX
Mouse Port interface Test Passed
1. No action
086-001-XXX
Mouse Port interface Presence
1. Mouse
2. System board
086-032-XXX
Mouse Port interface Device controller
failure
1. Mouse
2. System board
086-035-XXX
Mouse Port interface Reset
1. Mouse
2. System board
086-040-XXX
Mouse Port interface IRQ failure
1. Run Setup
2. Mouse
3. System board
086-195-XXX
Mouse Port interface Test aborted by user
1. Information
2. Re-start the test, if necessary
086-196-XXX
Mouse Port interface test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
64 Hardware Maintenance Manual