Diagnostic Error Code FRU/Action
018-0XX-XXX
PCI Card Failure
1. Riser card, if installed
2. System board
018-195-XXX
PCI Card Test aborted by user
1. PCI card
2. Information
3. Re-start the test, if necessary
018-196-XXX
PCI Card test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
018-197-XXX
PCI Card test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
018-198-XXX
PCI Card test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 5, “Using the IBM Setup
Utility,” on page 19
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Go to “Undetermined problems” on page
89
018-199-XXX
PCI Card test failed, cause unknown
1. Go to “Undetermined problems” on page
89
2. Flash the system and re-test. See “Flash
update procedures” on page 148
3. Replace component under function test
018-250-XXX
PCI Card Services error
1. PCI card
2. Riser card, if installed
3. System board
020-000-XXX
PCI Interface Test Passed
1. No action
020-0XX-XXX
PCI Interface error
1. PCI card
2. Riser card, if installed
3. System board
020-195-XXX
PCI Test aborted by user
1. Information
2. Re-start the test, if necessary
020-196-XXX
PCI test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file

Chapter 7. Symptom-to-FRU Index 59