conditions for connection to its network. It indicates no endorsement of
the product by Telecom, nor does it provide any sort of warranty. Above
all, it provides no assurance that any item will work correctly in all
respects with another item of Telepermitted equipment of a differentmake
or model, nor does it imply that any product is compatible with all of
Telecoms network services.
2. This equipment is not capable under all operation conditions of correct
operation at the higher speeds for which it is designed. The 33.6 kbit/s
and 56 kbit/s connections are likely to be restricted to lower bit rates
when connected to some PSTN implementations. Telecom will accept no
responsibility should difficulties arise in such circumstances.
3. This equipment may not provide for the effective hand-over of a call to
another device connected to the same line.
4. Under power failure conditions, this telephone may not operate. Please
ensure that a separate telephone, not dependent on local power is
available for emergency use.
5. Some parameters required for compliance with Telecoms Telepermit
requirements are dependent on the equipment (PC) associated with this
device. The associated equipment shall be set to operate within the
following limits for compliance with Telecoms specifications:
vThere shall be no more than 10 call attempts to the same number within
any 30-minute period for any single manual call initiation.
vThe equipment shall go on-hook for a period of not less than 30 seconds
between the end of one attempt and the beginning of the next attempt
to the same number.
6. Some parameters required for compliance with Telecoms Telepermit
requirements are dependent on the equipment (PC) associated with this
device. In order to operate within the limits for compliance with Telecoms
specifications, the associated equipment shall be set to ensure that
automatic calls to different numbers are spaced such that there is no less
than 5 seconds between the end of one call attempt and the beginning of
another.
7. This equipment shall not be set up to make automatic calls to Telecoms
111emergency service.
8. Some parameters required for compliance with Telecoms Telepermit
requirements are dependent on the equipment (PC) associated with this
device. In order to operate within the limits for compliance with Telecoms
specifications, the associated equipment shall be set to ensure that calls are
answered between 3 and 30 seconds of receipt of ringing.
For the modem with approval number PTC 211/01/004
The grant of a Telepermit for any item of terminal equipment indicates only
that Telecom has accepted that the item complies with minimum conditions
AppendixB. Product warranties and notices 61