SAN Architecture must meet RPQ criteria

Limit number of paths for Xsan/StorNext clients to four

This is to limit both complexity and the amount of time required to initialize clients on the SAN

Redundant Meshed Fibre Channel SAN (cross-connected)

RDAC MPP supports this configuration

Some IBM documentation may seem to preclude this, but those documents are based on an old non-“mpp” version of RDAC

Limits cause for failover to Controller failure

Specific Firmware, software, and Operating System Levels

IBM Storage

 

 

 

DS5100/DS5300

DS3400

DS5020

Future

DS4700

 

 

DS3400

DS4700

DS5020

DS5100

base

performance

DS5300

enhanced performance

 

Burst I/O rate

 

 

 

 

 

 

 

 

 

 

 

 

 

cache reads

110,000

120,000

200,000

 

650,000

700,000

 

 

(IOPS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sustained I/O rate

21,000

39,250

50,000

 

76,000

170,000

 

 

disk reads

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sustained I/O rate

4,500

9,350

9,500

 

20,000

38,000

 

 

disk writes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

448

 

 

Drives

 

48 SAS/SATA

 

112 FC/SATA

112

 

256

 

FC/SATA/FDE

 

 

 

 

FC/SATA/FDE

 

FC/SATA/FDE

 

/SSD*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(480) SATA*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burst throughput

 

1,600

 

1,550MB/s

 

3,700 MB/s

 

 

1,600MB/s

 

6,400 MB/s

 

 

 

 

 

 

 

 

 

 

cache read

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sustained

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

throughput

 

925

 

980MB/s

 

1,600 MB/s

 

 

1,600MB/s

 

6,400 MB/s

 

 

disk read

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sustained

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

throughput

 

720

 

850 MB/s

 

1,400 MB/s

 

 

1,300 MB/s

 

5,300 MB/s

 

 

 

 

 

 

 

 

 

 

disk write

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Host ports

 

4

 

4

 

4

 

 

8

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Media Storage Solution Installation Guide

 

 

 

 

 

7

 

 

© Copyright 2010, IBM Corporation. All rights reserved.

 

 

 

 

 

 

 

 

Page 7
Image 7
IBM DS5000, DS3000, DS4000 manual SAN Architecture must meet RPQ criteria, IBM Storage