SERIAL INTERFACE DEVELOPERS GUIDE
Size: 1 Word
Description: The member is divided into the following bit fields.
Fan Speed Index: (Bits 0 - 2) Current internal fan speed index. Read only data member.
Base NUC table: (Bits 3 - 8) Current base NUC index. Read only data member.
Limit NUC table: (Bits 9 - 14) Current limit NUC index. Read only data member.
No Refresh: (Bit 15) Set to disable automatic NUC refreshes. Only use this bit during specific
operations (defective pixel detection). Then clear when done.
6.2.18 CameraConfig.radSWInfo
Type: UWord16
Size: 1 Word
Description: OEM radiometric software version ID of the loaded embedded application. Read only
data member.
6.2.19 CameraConfig.alarm
Type: UWord16
Size: 1 Word
Description: This member is divided into the following bit fields for alarm state monitoring and other
miscellaneous settings. Read only data member(s).
Overtemp Alarm State: (Bit 0) Current overtemp alarm state.
Overtemp Acknowledge Alarm State: (Bit 1) Camera software acknowledge.
Battery Level State: (Bit 2) Low battery state value.
Battery Level Acknowledge State: (Bit 3) Camera software acknowledge.
FPA TEC Disable State: (Bit 4) TEC disable state (due to over temp condition).
Reserved Bits: (Bits 5 – 15).
6.2.20 CameraConfig.calFlagRefs
Type: UWord16
Size: 1 Word
Description: Calibration flag ADC reference settings as copied from the active NUC mode. These
settings are used in subsequent calibrations that incorporate the internal calibration flag. The variable
is divided as follows. Read only data member.
Cold Reference Setting: (Bits 0 – 7)
Hot Reference Setting: (Bits 8 – 15)
6.2.21 CameraConfig.fpaInfo
Type: UWord16
Size: 1 Word
Description: This value is broken into FPA type and sub-type as configured by the manufacturer/OEM.
The value is read on boot from the DSP data flash and can be used by the host to configure host
application settings. The variable is divided as follows. Read only data member.
FPA Type Identifier: (Bits 0 – 3)
24