Table 7. Error messages (3 of 4)

Error

Description

Action

 

 

 

Error to parse event

The probe cannot parse the

Check that the Nortel CNM

completely

alarm; this is probably because

server is running correctly.

Failed to parse event

the alarm is not in a format that

 

the probe can understand.

 

completely

 

 

 

Name is null, cannot

 

 

create Element

 

 

NetcoolIRPManager:

 

 

Category Value NOT

 

 

supported: Discarding

 

 

Alarm

 

 

NetcoolIRPManager:

 

 

Error when parsing

 

 

event

 

 

NetcoolIRPManager:

 

 

Failed to send event

 

 

 

 

 

Failed to get timeout

The Timeout property has not

Check the value for the Timeout

property value,

been set.

property; change this value if

defaulting to 0

 

necessary.

 

 

 

Failed to find the

The probe could not get the

Check the value for the

AlarmIRP object

AlarmIRP object using the

AlarmIrpName property;

 

EntryPoint IRP.

change this value if necessary.

 

 

 

Failed to find the

The probe could not get the

Check the value for the

NotificationIRP

NotificationIRP object

NotificationIrpName

object

using the EntryPoint IRP.

property; change this value if

 

 

necessary.

 

 

 

Failed to perform

The probe could not

Check the value for the Resynch

resynch

resynchronize the alarms with

property; change this value if

 

device.

necessary.

 

 

 

Failed to narrow

The probe has failed to get the

Check the value for the

Security IRP

EntryPointIRP object.

SecurityIrpFtpCommand

interface

 

property; change this value if

SECURITY: Failed to

 

necessary.

 

 

get IRP object :

 

 

SECURITY: Unknown

 

 

exception occured

 

 

 

 

 

NetcoolIRPManager:

This message is generated by

This message is intended for use

Stack Trace to stder:

the Netcool IRP Manager.

when debugging.

 

 

 

NetcoolIRPManager:

The probe has failed to get the

Check the value for the

Failed to retrieve

EntryPointIRP object.

SecurityIrpFtpCommand

EntryPointIRP object

 

property; change this value if

from security

 

necessary.

interface:

 

 

 

 

 

Probe for Nortel CNM 19