IBM Netcool/OMNIbus Probe for Nortel CNM manual Filtering notifications and alarms

Models: Netcool/OMNIbus Probe for Nortel CNM

1 34
Download 34 pages 40.61 Kb
Page 12
Image 12
Filtering notifications and alarms

Filtering notifications and alarms

The NotificationFilter and AlarmFilter properties allow you to specify what notifications and alarms the probe expects from the device. When you use these properties, you must use the actual token names. For example, the token h represents the element NV_PERCEIVED_SEVERITY; so, to specify that the probe is only sent notifications with a perceived severity of 3, you must set the NotificationFilter property to $h == 3.

You can specify more complex filters using and and or statements; for example, to specify that the probe is sent notifications with a perceived severity of 3 or 4, you must set the NotificationFilter property to $h == 3 or $h == 4.

Note: The filtering of elements sent from the device can only be configured at the Nortel CNM 3GPP2 (CORBA). For details of the syntax required for filtering the object classes refer to your CORBA documentation, or contact your system administrator.

Table 3 displays the token mappings for use with the AlarmFilter and

NotificationFilter properties.

Table 3. Token mappings (1 of 2)

Element

Token

 

 

NV_NOTIFICATION_ID

a

 

 

NV_EVENT_TIME

b

 

 

NV_SYSTEM_DN

c

 

 

NV_MANAGED_OBJECT_CLASS

d

 

 

NV_MANAGED_OBJECT_INSTANCE

e

 

 

NV_ALARM_ID

f

 

 

NV_PROBABLE_CAUSE

g

 

 

NV_PERCEIVED_SEVERITY

h

 

 

NV_SPECIFIC_PROBLEM

i

 

 

NV_ADDITIONAL_TEXT

j

 

 

NV_ACK_TIME

k

 

 

NV_ACK_USER_ID

l

 

 

NV_ACK_SYSTEM_ID

m

 

 

NV_ACK_STATE

n

 

 

NV_COMMENTS

o

 

 

NV_BACKED_UP_STATUS

p

 

 

NV_BACK_UP_OBJECT

q

 

 

NV_THRESHOLD_INFO

r

 

 

NV_TREND_INDICATION

s

 

 

6 Netcool/OMNIbus Probe for Nortel CNM Reference Guide

Page 12
Image 12