IBM Netcool/OMNIbus Probe for Nortel CNM Properties and command line options 3 of, Property name

Models: Netcool/OMNIbus Probe for Nortel CNM

1 34
Download 34 pages 40.61 Kb
Page 19
Image 19

Table 5. Properties and command line options (3 of 4)

Property name

Command line option

Description

 

 

 

Password string

-password string

Password required with the Username

 

 

property to log in to the system.

 

 

The default is "".

 

 

Note: Specify the password encrypted

 

 

using the nco_g_crypt utility. For

 

 

details about this utility, see IBM

 

 

Tivoli Netcool/OMNIbus

 

 

Administration Guide, SC23-6371.

 

 

 

Resynch string

-resynch string

Specifies whether the probe should

 

 

resynchronize the events in the Nortel

 

 

CNM system:

 

 

true - probe resynchronizes events in the

 

 

system

 

 

false - probe does not resynchronize

 

 

events in the system

 

 

he default is false.

 

 

 

Retry string

-retry string

Specifies whether the probe attempts to

 

 

reconnect to the system following a

 

 

timeout:

 

 

false - probe does not attempt to

 

 

reconnect to the system

 

 

true - probe attempts to reconnect to the

 

 

system

 

 

The default is false.

 

 

 

SecurityIrpFtp

-securityirp

FTP command to retrieve the Nortel

Command string

ftpcommand string

Security IRP IOR file.

 

 

The default is "" (the probe retrieves IOR

 

 

file from the default local location).

 

 

 

Timeout integer

-timeout integer

Time (in seconds) that the probe allows the

 

 

port to be silent before disconnecting.

 

 

The default is 0 (probe never disconnects).

 

 

 

Probe for Nortel CNM 13

Page 19
Image 19
IBM Netcool/OMNIbus Probe for Nortel CNM Properties and command line options 3 of, Property name, Command line option