Leadership enterprise server with significantly lower cost of ownership in a highly available and expandable,
(* When available in 2Q/2010) | 1333MHz RDIMM |
|
| 1333MHz UDIMM |
| 1066MHz RDIMM | |||||
| 2GB |
| 2GB | *8GB | |||||||
| 1.5V; |
|
| *4GB | *16GB | ||||||
| 2GB |
|
|
|
|
|
|
| |||
| 2GB |
|
|
|
|
|
|
| |||
| 2GB |
|
|
|
|
|
|
| |||
| 4GB |
|
|
|
|
|
|
| |||
| 4GB |
|
|
|
|
|
|
| |||
| 8GB |
|
|
|
|
|
|
| |||
| *8GB |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||||
Supports 1333MHz with 2 DIMMs per | L5640 and X56xx processors support 2DPC at 1333MHz; | ||||||||||
channel | X55xx processors support 2DPC at 1333MHz via the special bid process | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |
Online |
|
|
|
|
| No |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
Memory mirroring supported / # of DIMM | Yes / 1 channel (3 slots per processor) active, 1 spare, 1 unused | ||||||||||
sockets reserved for mirroring | |||||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| ||||||
# of HDD drive bays total / available | 16 / 16 |
| 8 / 8 | ||||||||
|
|
|
|
|
|
|
|
|
| ||
# of 5.25" bays total / available |
|
|
|
| 1 / 1 |
|
|
| |||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| ||||||
|
| SAS/SATA |
|
| 400GB (8 x 50GB) | ||||||
Maximum drive capacity (supports mixing | SAS/SATA |
|
|
| |||||||
| 4.0TB | (8 x 500GB) |
| 800GB (16 x |
| ||||||
SAS/SATA/SSD) | 8.0TB (16 x |
|
|
| |||||||
|
| 50GB) |
| ||||||||
| 500GB) |
|
|
| |||||||
|
| internal tape drive |
|
|
|
| internal tape drive | ||||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| ||||||
| 500GB – 7.2K |
|
| ||||||||
Drive capacities supported |
|
| 160, 500GB – 7.2K | ||||||||
73.4, 146.8, 300GB – 10K |
|
|
| 50GB | |||||||
|
| 300GB – 10K |
|
| |||||||
| 73.4, 146.8GB |
|
|
|
| ||||||
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| |||
# of HDDs standard |
|
|
|
| None (all models open bay) |
|
|
| |||
|
|
|
|
|
|
|
|
| |||
# of optical drives standard |
|
|
|
| None (optional |
|
|
| |||
|
|
|
|
|
|
|
|
| |||
# of diskette drives standard |
|
|
|
| None (optional) |
|
|
| |||
|
| ||||||||||
Internal backup supported | One tape drive (DDS Gen 5, DDS Gen 6) or RDX removable disk cartridge | ||||||||||
|
| ||||||||||
Storage technology | |||||||||||
|
|
|
|
|
|
|
|
| |||
Integrated disk controller |
|
|
|
| LSI 1068 |
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||
# of disk drives supported per port |
|
|
|
|
| 1 |
|
|
| ||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| |||||||
|
|
| (no cache) |
|
| ||||||
| ServeRAID- |
|
| (256MB cache) |
| (512MB cache) | |||||
|
| optional battery— |
|
| |||||||
| BR10il v2 (no |
|
| optional battery— |
| optional battery— | |||||
|
|
|
| ||||||||
|
|
|
| ||||||||
|
| optional |
|
| |||||||
Integrated RAID controller standard | 0/1/1E, 3Gbps; |
|
| optional RAID- |
| optional RAID- | |||||
| with SED, 6Gbps; |
|
| ||||||||
| supports 4 drives |
|
| 6/60 with SED, |
| 6/60 with SED, | |||||
|
| supports 16 drives |
|
| |||||||
| (A2x) |
|
| 6Gbps; supports |
| 6Gbps; supports | |||||
|
| (B2x, C2x, D2x, |
|
| |||||||
|
|
|
| 16 drives (F2x, |
| 16 drives (J2x, | |||||
|
|
| H2x, N2x) |
|
| ||||||
|
|
|
| G2x) |
|
| L2x, M2x) | ||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||
Optional integrated RAID controllers |
| ||||||||||
| B2x, C2x, D2x, F2x, G2x, | ||||||||||
supported |
| B2x, C2x, D2x, H2x, N2x) | |||||||||
|
|
| H2x, N2x) | ||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| ||||||||
External disk drives supported | Yes, via the optional 3Gbps | ||||||||||
|
|
| SAS/SATA; adds |
|
| ||||||
|
| ||||||||||
# of adapter slots total / available | 4 / 4 (2 / 2 when using the CTO Emulex 10GbE Integrated Virtual Fabric Adapter) | ||||||||||
|
| ||||||||||
# of PCIe x16 Gen 2 slots (16GBps) | None standard (1 or 2 via optional risers in place of the x8 PCIe risers) | ||||||||||
|
| ||||||||||
# of PCIe x8 Gen 2 slots (8GBps) | 4 via 2 risers (2 | ||||||||||
|
| ||||||||||
# of | None standard (1 or 2 via optional risers in place of the PCIe risers) | ||||||||||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| 17 |
Please see the Legal Information section for important notices and information.