INSTALLATION AND CONNECTIONS
■Power supply connectionsUse the optional PS-125 DC power supply with a 25 A
capacity when operating the transceiver with AC
power. Refer to the diagrams below.
CAUTION: Before connecting the DC power
cable, check the following important items. Make
sure:
•The [POWER] switch is OFF.
•Output voltage of the power source is 12–15 V
when you use a non-Icom power supply.
•DC power cable polarity is correct.
Red : positive +terminal
Black : negative _terminal
CONNECTING ADC POWER SUPPLY
to DC power
socket
A DC power supply
AC outlet
AC cable 30 A fuses
Supplied
DC power cable
13.8 V; at least 23 A
Black
_Red
+
Transceiver
CONNECTING AVEHICLE BATTERY
12 V
battery Supplied
DC power cable
+ red
_ black Crimp
Solder
Grommet
NEVER connect to
a 24 V battery.
NOTE: Use terminals for
the cable connections.
NEVER connect to a battery without supplied DC fuses,
otherwise a fire hazard may occur.
CONNECTING PS-125 DC POWER SUPPLY
PS-125
Connect to an AC outlet
using the supplied AC cable.
DC power cable
DC power
socket
Transceiver