31
5
RECEIVE AND TRANSMIT
■Dualwatch operationDualwatch monitors 2 frequencies with the same
mode simultaneously.
During dualwatch, both frequencies should be on the
same band, because the bandpass filter in the RF cir-
cuit is selected for the main readout frequency.
qSet a desired frequency.
wPush [DUALWATCH] for 1 sec.
•Equalized receive frequency and “” appear in
the LCD. This quick dualwatch function can be turned
OFF in set mode. (p. 69)
•Pushing [DUALWATCH] momentarily activates the du-
alwatch with the previously operated frequency.
eSet another desired frequency using the tuning
dial.
rAdjust [BAL] to set a suitable signal strength bal-
ance between the main and sub readout frequen-
cies.
•S-meter shows the combined signal strength.
tTo transmit on the sub readout frequency, push
[CHANGE] or [SPLIT].
RITfunction can be used for the main readout only.
∂TX function can be used for the transmit readout
(main readout when the split function is OFF; sub
readout when the split function is ON).
BWBW2.4k2.4k SFTSFT 0
FIL2FIL2
USBUSB
qw:pp
VFOVFO
TXTX
5656
1
USBUSB
USBUSB
USBUSB
FIL2FIL2
wq.wop.pp
wq.wop.pp
14.100.0014.100.00
14.100.0014.100.00
VFOVFO
DUAL-WDUAL-W
ANTANT
1
METERMETER
PoPo
P.AMPP.AMP
1
ATTATT
OFFOFF
DUAL-WDUAL-W
•Scanning during dualwatch
Scanning operates only for the main readout. To op-
erate the scan during dualwatch, scan on the main
readout and use the sub readout for your QSO using
both dualwatch and split frequency operation.
qProgram the desired programmed scan edges in
the same amateur band. See p. 53 for program-
ming.
•If you plan to operate a ∂F scan, programming the
scan edges may not be necessary.
wPush [SPLIT] to turn the split frequency function
ON.
•“ ” appears.
eSelect VFO mode for the main readout.
rSet the desired operating frequency for the main
readout.
tPush [DUALWATCH] for 1 sec.
•The main and sub readout frequencies are equalized
and the dualwatch function is turned ON.
yPush [(F-4)SCAN] to select the scan screen.
•Push [EXIT/SET] several times to close a multi-func-
tion screen, if necessary.
uPush [(F-1)PROG] or [(F-2)∂F] to start the pro-
grammed scan or ∂F scan, respectively.
•Scan activates on the main readout between the pro-
grammed scan edges or within the ∂F span.
•Transmitting on the sub readout stops the scan.
iTo cancel the scan, push [EXIT/SET].
wq.wop.pp
BWBW2.4k2.4k SFTSFT 0
FIL2FIL2
USBUSB
qw:pp
VFOVFO USBUSB
USBUSB
USBUSB
FIL2FIL2
wq.wtp.pp
14.100.0014.100.00
14.100.0014.100.00
VFOVFO
SPLITSPLIT
1
1
DUAL-WDUAL-W
PROGPROG ∂FFINEFINE ∂F SPANF SPAN SETSET
SCANSCAN
TXTX
ANTANT
1
COMPCOMP
OFFOFF
WIDEWIDE
METERMETER
PoPo
P.AMPP.AMP
1
AGCAGC
MIDMID
ATTATT
OFFOFF
VOXVOX
OFFOFF
PROGRAM SCANPROGRAM SCAN
∂FSpanSpan:±±10kHz10kHz
ProgrammedProgrammedP1:P1:21.000.00MHz21.000.00MHz
scanscanedgesedgesP2:P2:21.450.00MHz21.450.00MHz
wq.wop.pp
BWBW2.4k2.4k SFTSFT 0
FIL2FIL2
USBUSB
qw:pp
VFOVFO USBUSB
USBUSB
USBUSB
FIL2FIL2
wq.wop.pp
14.100.0014.100.00
14.100.0014.100.00
VFOVFO
SPLITSPLIT
1
1
DUAL-WDUAL-W
TXTX
ANTANT
1
METERMETER
PoPo
P.AMPP.AMP
1
ATTATT
OFFOFF
BWBW2.4k2.4k SFTSFT 0
FIL2FIL2
USBUSB
qw:pp
VFOVFO USBUSB
USBUSB
USBUSB
FIL2FIL2
wq.wop.pp
14.100.0014.100.00
14.100.0014.100.00
VFOVFO
qr.wpt.pp
SPLITSPLIT
1
1
TXTX
ANTANT
1
METERMETER
PoPo
P.AMPP.AMP
1
ATTATT
OFFOFF
SPLITSPLIT