61
7SCANS
■Scan set modeScan set mode is used for programming scanning
speed and scan resume condition.
•Scan speed
The transceiver has 2 speeds for scanning, high and
low.
qPush [EXIT/SET] several times to close a multi-
function screen, if necessary.
wPush [(F-5)SCAN] to select the scan screen.
ePush [(F-5)SET] to select the scan set mode
screen.
rPush [(F-1)Y] to select the scan speed item.
tRotate the tuning dial to select the scan speed.
•Push [(F-3)DEF] to select the default condition.
yPush [EXIT/SET] to exit the scan set mode.
•Scan resume condition
This item sets the scan resume function ON or OFF.
ON: scan resumes 10 sec. after stopping on a signal
(or 1 sec. after a signal disappears); OFF: scan does
not resume after stopping on a signal.
qPush [EXIT/SET] several times to close a multi-
function screen, if necessary.
wPush [(F-5)SCAN] to select the scan screen.
ePush [(F-5)SET] to select the scan set mode
screen.
rPush [(F-2)Z] to select the scan resume condition
item.
tRotate the tuning dial to turn the scan resume
function ON or OFF.
•Push [(F-3)DEF] to select the default condition.
yPush [EXIT/SET] to exit the scan set mode.
éèDEF
SCAN SET
COMPCOMP
OFFOFF
WIDEWIDE
AGCAGC
MIDMID
VOXVOX
OFFOFF
SCAN SpeedSCAN Speed HIGHHIGH
SCAN ResumeSCAN Resume ONON
éèDEF
SCAN SET
COMPCOMP
OFFOFF
WIDEWIDE
AGCAGC
MIDMID
VOXVOX
OFFOFF
SCAN SpeedSCAN Speed HIGHHIGH
SCAN ResumeSCAN Resume ONON
PROGPROG ∂FFINEFINE ∂F SPANF SPAN SETSET
SCANSCAN
COMPCOMP
OFFOFF
WIDEWIDE
AGCAGC
MIDMID
VOXVOX
OFFOFF
∂FSpanSpan:±±10kHz10kHz
ProgrammedProgrammedP1:P1:0.500.00MHz0.500.00MHz
scanscanedgesedgesP2:P2:29.999.99MHz29.999.99MHz
■Tone scan
The transceiver can detect the subaudible tone fre-
quency in a received signal. By monitoring a signal
that is being transmitted on a repeater input fre-
quency, you can determine the tone frequency re-
quired to access the repeater.
qSet the desired frequency or memory channel to
be checked for a tone frequency.
wPush [AM/FM] several times to select FM mode.
ePush [TONE] for 1 sec. to enter the tone frequency
screen.
rPush [(F-1)Y] or [(F-2)Z] to check the repeater
tone frequency or tone squelch frequency, respec-
tively. (pgs.47, 48)
tPush [(F-5)T-SCAN] to start the tone scan.
•“SCAN” flashes while scanning.
yWhen the tone frequency is detected, the tone
scan pauses.
•The tone frequency is set temporarily on a memory
channel. Program into the memory channel to store the
tone frequency permanently.
•The decoded tone frequency is used for the repeater
tone frequency or tone squelch frequency.
uTo stop the scan, push [(F-5)T-SCAN].
iPush [EXIT/SET] to exit the tone frequency
screen.
TONE FREQUENCYTONE FREQUENCY
188.8Hz188.8Hz SCANSCAN
88.5Hz88.5HzT-SQL TONET-SQL TONE
REPEATER TONEREPEATER TONE
TONETONE
AGCAGC
FASTFAST
VOXVOX
OFFOFF
T-SCANT-SCAN
T-SCANT-SCAN
éèDEFDEF
TONE FREQUENCYTONE FREQUENCY
88.5Hz88.5Hz
88.5Hz88.5HzT-SQL TONET-SQL TONE
REPEATER TONEREPEATER TONE
TONETONE
AGCAGC
FASTFAST
VOXVOX
OFFOFF