■Spectrum scope screenThis function allows you to display the relative
strengths of signals around the center frequency. The
span can be set to ±12.5 kHz, ±25 kHz, ±50 kHz and
±100 kHz. Ideal for monitoring band conditions in an
instant.
qPush [EXIT/SET] several times to close a multi-
function screen, if necessary.
wPush [(F-1)SCOPE] to select the scope screen.
ePush [(F-1)SPAN] several times to select the
scope span.
rPush [(F-2)ATT] several times to activate an atten-
uator or turn the attenuator OFF.
•10, 20 and 30 dB attenuators are available.
tPush [(F-3)MARKER] several times to select the
marker (sub readout or transmit frequency) or turn
the marker OFF.
•“TX MARKER” displays the marker at the transmit fre-
quency.
•“SUB MARKER” displays the marker at the sub readout
frequency.
yPush [(F-4)HOLD] to freeze the current spectrum
waveform.
•“HOLD” appears while the function is in use.
uPush [EXIT/SET] to exit the scope screen.
•Spectrum scope during transmitting
The spectrum scope shows the transmit signal wave-
form while transmitting. This can be deactivated if de-
sired.
When “OFF” is selected, the spectrum scope holds
the received waveform while transmitting and does
not show the transmit waveform.
qCall up the scope screen as described at left.
wPush [(F-5)SET] to select the spectrum scope set
mode.
ePush [(F-1)∫] to select the “Scope during Tx” item.
rRotate the tuning dial to display the spectrum
scope while transmitting or not.
tPush [EXIT/SET] to exit spectrum scope set mode.
•Maximum level hold function
The spectrum scope shows the peak level holding
function. Peak levels are displayed in the background
of the current spectrum in a different color until the re-
ceive frequency changes. This can be deactivated if
desired.
qCall up the scope screen as described at left.
wPush [(F-5)SET] to select the spectrum scope set
mode.
ePush [(F-2)√] to select the “Max Hold” item.
rRotate the tuning dial to turn the peak level holding
function ON or OFF.
tPush [EXIT/SET] to exit spectrum scope set mode.
If a strong signal is received, a ghost waveform
may appear. Push [(F-2)ATT] several times to acti-
vate the spectrum scope attenuator in this case.
DEFDEF
éè
VOXVOX
OFFOFF
COMPCOMP
OFFOFF
WIDEWIDE
AGCAGC
MIDMID
ScopeScopeduringduringTxTx ONON
MaxMaxHoldHold ONON
SCOPESCOPESETSET
DEFDEF
éè
VOXVOX
OFFOFF
COMPCOMP
OFFOFF
WIDEWIDE
AGCAGC
MIDMID
ScopeScopeduringduringTxTx ONON
MaxMaxHoldHold ONON
SCOPESCOPESETSET
BWBW2.4k2.4k SFTSFT 0
FIL2FIL2
USBUSB
qw:pp
TXTX
VFOVFO USBUSB
USBUSB
USBUSB
FIL2FIL2
qr.qot.pp
qr.wpq.pp
14.100.0014.100.00
14.100.0014.100.00
1
1
VFOVFO
SUBSUB
MARKERMARKER
ATTATT
10dB10dB
HOLDHOLD
GridGrid
2.5k2.5k
10dB10dB
+12.5k+12.5k
-12.5k-12.5k SPECTRUM SCOPESPECTRUM SCOPE
ANTANT
1
METERMETER
PoPo
ATTATT
OFFOFF
VOXVOX
OFFOFF
COMPCOMP
OFFOFF
WIDEWIDE
AGCAGC
MIDMID
P.AMPP.AMP
1
HOLDHOLD SETSET
SPANSPAN ATTATT MARKERMARKER
Appears when the
marker is out of range.
Sub readout
or TX marker
Appears when the
marker is out of range.
ANTANT
1
METERMETER
PoPo
ATTATT
OFFOFF
VOXVOX
OFFOFF
COMPCOMP
OFFOFF
WIDEWIDE
BWBW2.4k2.4k SFTSFT 0
FIL2FIL2
USBUSB
qw:pp
AGCAGC
MIDMID
TXTX
VFOVFO USBUSB
USBUSB
USBUSB
FIL2FIL2
qr.qot.pp
qr.wpq.pp
14.100.0014.100.00
14.100.0014.100.00
1
1
VFOVFO
GridGrid
2.5k2.5k
10dB10dB
+12.5k+12.5k
-12.5k-12.5k SPECTRUM SCOPESPECTRUM SCOPE
HOLDHOLD SETSET
P.AMPP.AMP
1
SPANSPAN ATTATT MARKERMARKER