5-2 SOFTWARE ADJUSTMENT (FREQUENCY)

Select the adjustment item with [] / [] keys, then set the value with [] / [] keys on the connected PC.

 

 

 

 

 

 

MEASUREMENT

 

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

 

VALUE

 

UNIT

OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

PLL LOCK

 

1

• Operating CH. : 16

PC

Check the LVIN Data cell's

1.5–3.0 V [USA]

VOLTAGE

 

 

• Receiving

 

screen

va l u e i n t h e I / O c h e ck

1.85–3.35 V [Others]

 

 

 

 

 

 

window.

(Verify)

 

 

 

 

 

 

Click the "I/O check button"

 

 

 

 

 

 

 

 

 

2

• Operating CH. : 16

 

1.4–2.9 V

 

 

 

on the CS-M90/GM1600

 

 

 

• RF power

: Low

 

ADJ's screen (see page

(Verify)

 

 

 

• Transmitting

 

 

5-3) to open the I/O check

 

 

 

 

 

 

 

window as below.

 

 

 

 

 

 

 

 

REFERENCE

 

1

• Operating CH. : 16

Top

Loosely couple the frequency

156.8000 MHz

FREQUENCY

 

 

• Connect the RF power meter or a 50

Panel

counter to the antenna

±500 Hz

[Ref. Freq.]

 

 

dummy load to the antenna connector.

 

conector.

 

 

 

 

• RF power

: Low

 

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

 

PLL LOCK VOLTAGE

NOTE: The above screen is an example.

Each transceiver has its own specific values.

5 - 4