5-2 SOFTWARE ADJUSTMENT (TRANSMITTING)

Select the adjustment item with [] / [] keys, then set the value with [] / [] keys on the connected PC.

 

 

 

 

 

MEASUREMENT

 

ADJUSTMENT

 

ADJUSTMENT CONDITION

 

 

VALUE

 

UNIT

OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT POWER

1

• Operating CH.

: 16

Top

Connect the RF power meter to

 

[RF Power (High)]

 

• RF power

: High

panel

the antenna connector.

2.0 W

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

[RF Power (Low)]

2

• Operating CH.

: 16

 

 

 

 

 

• RF power

: Low

 

 

0.75 W

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

FM DEVIATION

1

• Operating CH.

: 16

Top

Connect the FM deviation meter

±4.15–4.25 kHz

[MOD (Wide)]

 

• Set the FM deviation meter as;

panel

to the antenna connector through

 

 

 

HPF

: OFF

 

the attenuator.

 

 

 

LPF

: 20 kHz

 

 

 

 

 

De-emphasis : OFF

 

 

 

 

 

Detector

: (P±P)/2

 

 

 

 

 

• Connect the audio generator to

 

 

 

 

 

the [MIC/SP] jack through OPC-1028

 

 

 

 

 

and set as;

 

 

 

 

 

 

Frequency

: 1 kHz

 

 

 

 

 

Level

: 25 mV rms

 

 

 

 

 

• Transmitting

 

 

 

 

 

 

 

 

 

 

 

VOX

1

• Operating CH.

: 16

PC

Push the [ENTER] key on the keyboad

Automatic

[VOX]

 

• Set to VOX mode.

screen

of the connected PC.

adjustment

 

 

(Push [SQL] + [Hi/Lo].)

 

 

 

 

 

• No audio applied to the [MIC/SP]

 

 

 

 

 

jack.

 

 

 

 

 

 

 

 

 

 

 

5 - 5