Icom IC-T90A manual Detector, Coil, Tracking

Models: IC-T90A

1 57
Download 57 pages 40.24 Kb
Page 28
Image 28

ADJUSTMENT MODE ADJUSTMENTS (Continued)

The following adjustment must be performed at “ADJUSTMENT MODE”.

“DETECTOR COIL” adjustment must be performed on same channel as “DTCS DEVIATION ADJUSTMENT” (DT ch.).

 

 

 

 

 

MEASUREMENT

 

ADJUSTMENT

ADJUSTMENT

ADJUSTMENT CONDITION

VALUE

POINT

 

 

 

 

 

 

 

 

 

UNIT

LOCATION

 

UNIT

ADJUST

 

 

 

 

 

 

 

 

DETECTOR

1

• Displayed frequency :

AF

Connect a multime-

1.0 V

AF

L151

COIL

 

(DS ch.)

 

445.000 MHz

 

ter to

check

point

 

 

 

 

 

• Connect the SSG to the antenna

 

CP0.

 

 

 

 

 

 

 

connector and set as:

 

 

 

 

 

 

 

 

 

Level

 

: 1.0 µV*

 

 

 

 

 

 

 

 

 

 

 

(–47 dBm)

 

 

 

 

 

 

 

 

 

Modulation

: OFF

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF

1

• Displayed frequency :

AF

Connect a DC volt-

Maximum voltage

Top

[DIAL]

TRACKING

 

(TL ch.)

30.100 MHz

 

meter

or

oscillo

 

panel

 

 

 

• Connect the SSG to the antenna

 

scope to the IC151,

 

 

 

 

 

connector and set as:

 

pin 12 (“SD” line).

 

 

 

 

 

Level

 

: 0.5 µV*

 

 

 

 

 

 

 

 

 

 

 

(–113 dBm)

 

 

 

 

 

 

 

 

 

Modulation

: 1 kHz

 

 

 

 

 

 

 

 

 

Deviation

 

: ±3.5 kHz

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

• Displayed frequency :

 

 

 

 

Maximum voltage

 

[DIAL]

 

 

(TH ch.)

47.100 MHz

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

• Displayed frequency :

 

 

 

 

Maximum voltage

 

[DIAL]

 

 

(TL ch.)

48.100 MHz

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

• Displayed frequency :

 

 

 

 

Maximum voltage

 

[DIAL]

 

 

(TH ch.)

75.100 MHz

 

 

 

 

 

 

 

 

 

• Set the SSG as:

 

 

 

 

 

 

 

 

 

Level

 

: 1 µV*

 

 

 

 

 

 

 

 

 

 

 

(–107 dBm)

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

• Displayed frequency :

 

 

 

 

Maximum voltage

 

[DIAL]

 

 

(TL ch.)

76.100 MHz

 

 

 

 

 

 

 

 

 

• Set the SSG as:

 

 

 

 

 

 

 

 

 

Level

 

: 1 µV*

 

 

 

 

 

 

 

 

 

 

 

(–107 dBm)

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

• Displayed frequency :

 

 

 

 

Maximum voltage

 

[DIAL]

 

 

(TH ch.)

149.100 MHz

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

• Displayed frequency :

 

 

 

 

Maximum voltage

 

[DIAL]

 

 

(TL ch.)

150.100 MHz

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

• Displayed frequency :

 

 

 

 

Maximum voltage

 

[DIAL]

 

 

(TH ch.)

229.100 MHz

 

 

 

 

 

 

 

 

 

• Set the SSG as:

 

 

 

 

 

 

 

 

 

Level

 

: 3.2 µV*

 

 

 

 

 

 

 

 

 

 

 

(–97 dBm)

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

• Displayed frequency :

 

 

 

 

Maximum voltage

 

[DIAL]

 

 

(TL ch.)

280.100 MHz

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

• Displayed frequency :

 

 

 

 

Maximum voltage

 

[DIAL]

 

 

(TM ch.)

370.100 MHz

 

 

 

 

 

 

 

 

 

• Set the SSG as:

 

 

 

 

 

 

 

 

 

Level

 

: 0.5 µV*

 

 

 

 

 

 

 

 

 

 

 

(–113 dBm)

 

 

 

 

 

 

 

 

 

• Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*This output level of the standard signal generator (SSG) is indicated as SSG’s open circuit.

 

 

 

 

 

 

 

 

5 - 11

 

 

 

 

 

Page 28
Image 28