Icom IC-T90A manual Adjustment Procedures, Preparation, ‘ Required Test Equipment

Models: IC-T90A

1 57
Download 57 pages 40.24 Kb
Page 18
Image 18

SECTION 5 ADJUSTMENT PROCEDURES

5-1 PREPARATION

Some adjustments must be adjusted on the adjustment mode. When entering the adjustment mode, the 68 kΩ terminator (shown at page 5-2) is required.

REQUIRED TEST EQUIPMENT

EQUIPMENT

GRADE AND RANGE

EQUIPMENT

GRADE AND RANGE

 

 

 

 

 

 

DC power supply

Output voltage

: 11 V DC

Ammeter

Measuring capacity

: 10 A and 30 A

Current capacity

: 3 A or more

 

 

 

 

DC voltmeter

Input impedance

: 50 kΩ /V DC or better

 

 

 

 

Measuring range

: 1–10 W

 

 

 

 

 

 

Frequency range

: 300–3000 Hz

RF power meter

Frequency range

: 28–600 MHz

Audio generator

Measuring range

: 1–500 mV

(terminated type)

Impedance

: 50 Ω

 

 

 

 

 

SWR

: Less than 1.2 : 1

Standard signal

Frequency range

: 1–1300 MHz

 

 

 

Output level

: 0.1 µV–32 mV

 

Frequency range

: 0.1–600 MHz

 

generator (SSG)

 

 

(–127 to –17 dBm)

Frequency counter

Frequency accuracy : ±1 ppm or better

 

 

 

 

 

 

 

 

 

Sensitivity

: 100 mV or better

Oscilloscope

Frequency range

: DC–20 MHz

 

 

 

Measuring range

: 0.01–20 V

FM deviation meter

Frequency range

: 30–600 MHz

 

 

 

 

Measuring range

: 0 to ±10 kHz

Attenuator

Power attenuation

: 40 or 50 dB

 

 

 

 

 

 

 

ENTERING THE ADJUSTMENT MODE q Connect a 68 kΩ terminator to the [SP] jack.

w Push and hold the [SQL] and [8] keys, and then turn power ON.

OPERATION ON THE ADJUSTMENT MODE

Change the adjustment value

: [DIAL]

Change the adjustment channel or item [UP]

: [VFO] key

Change the adjustment channel or item [DOWN]

: [MR] key

Verify the setting condition

: [8] key

OPERATION ON THE “OUTPUT POWER” ADJUSTMENT

When adjusting the “OUTPUT POWER” adjustment, need to change the adjustment channel indicator manually.

When displayed channel indicator “DH” on the LCD at first, push the “0” or “.” keys to change the channel indicator as follow.

Pushing key

LCD (Before)

LCD (After)

 

 

 

“0” key

DH

PH

 

 

 

“0” key

PH

DH

 

 

 

 

 

 

Pushing key

LCD (Before)

LCD (After)

 

 

 

“.” key

DH

DL

 

 

 

“.” key

DL

DE

 

 

 

“.” key

DE

DH

 

 

 

5 - 1