Citizen CLP-7002, CLP-7401 user manual Adjustable Sensor For CLP-7001/7401, Operating procedure

Models: CLP-7401 CLP-7001 CLP-7002

1 76
Download 76 pages 41.21 Kb
Page 47
Image 47

Chapter 4 Printer Adjustments

4Adjustable Sensor (For CLP-7001/7401)

The adjustable sensor is the optional for CLP-7002.

Adjustable knob

Mark (yellow)

Upper guide rail

Operating procedure:

1.Move the adjustable sensor to your required detection position by tuning the adjustable knob. Measure your detection position beforehand. To set t he detection position, align the scale marking on top of the upper guide rail with the sensor position mark (yellow) on the upper of the sensor. The movable range of the adjustable sensor is shown below.

2.Set the liner and close the upper guide rail and set voltage to 3V.

For voltage setting, see Section 5: System Maintenance Mode, Chapter 2.

Left edge of paper

0 mm

118 mm (max. paper width)

59 mm (sensor usable range)

Adjustable sensor movable range