Citizen CLP-7001, CLP-7401, CLP-7002 user manual System Maintenance Mode

Models: CLP-7401 CLP-7001 CLP-7002

1 76
Download 76 pages 41.21 Kb
Page 31
Image 31

Chapter 2 PrinterOparetion

5 System Maintenance Mode

1 Native

Normally ‘NativeON’ is used. See the Command Reference for details.

2 Feed amount

See the Command Reference for details.

3 Command code

Normally ‘CmndSTD’ is used. See the Command Reference for details.

4 For adjustable sensor, the voltage setting must be done each time ‘AJSensOF’ is changed to ‘AJSensON, and vice versa.

5 Voltage setting

In the voltage setting, adjust the paper gap and black line adjustment controls so that the voltages of both ‘PE’ and ‘BL’ displayed on the LCD screen can read 3.0V to 3.3V.

1.Set the liner (glassine paper) only that has been removed from the label. (For th eblack line paper, position the black line so that it does not come to the paper sensor.)

2.Set each level to 3.0V to 3.3V with the controls.

Paper gap sensor adjustment control

Black line sensor adjustment control

28

Page 31
Image 31
Citizen CLP-7001, CLP-7401, CLP-7002 user manual System Maintenance Mode