ICP DAS USA DFS2H324J2A Condensing Unit, pump, WiringDiagramHeat, Models2, MainsACSupply, Or Un

Models: DFS2H318J2A DFS2H324J2A DFS2A324J2A DFS2A318J2A

1 15
Download 15 pages 47.09 Kb
Page 9
Image 9
INDOOR UN

 

TH1

 

TH2

1

 

IT

TH3

INDOOR UN

 

J6

 

 

 

 

 

 

J8 J7

 

J18

K6

K5

K1

K2

 

 

 

5

4

3

2

 

 

 

FAN

H.L.T.V

RVS

COMP.

 

BLK

YEL

WH

4RED5 GREEN

6 GR/YEL

GND

TB

1 2 3OR

J12

STEPPER

MOTOR

J14

 

 

 

 

 

1 3

 

 

 

 

+12V

-12V

 

RED

BLK

 

J5

 

 

 

1 3

 

 

 

J1

 

321

 

 

 

J11

K8

 

K9

 

 

K7

1

5

4

6

WH

BLUE

 

RED

 

 

BLK

+30V

FAN1

 

FAN2

 

 

FAN3

J3

1

2

3

4

5

J4

1

2

3

4

5

6

 

CDV 03 +D ER

NTR CD KLB

PSV LEY

CDV 21+ TH W

 

 

 

TAC 671 Main Board

TAC672B

MotorControl

TAC 670 control

 

 

-16AWG

-14 AWG

-12 AWG

WIRES18AWG

- Splice

- Terminal(Unmarked)

FactoryWiring

FieldControlWiring

FieldPowerWiring

 

LEGEND

ALLOTHER

 

 

 

 

 

 

***

**

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CompressorCapacitor

 

 

ReversingValveSolenoid

LowTemp.Valve

 

 

airsensor coil sensor Outdoorcoilsensor unit1circuit

unit2circuit

 

 

Compressor

Capacitor

 

TerminalBlock

brushlessDC

Condensing Unit

pump

BLK

WiringDiagramHeat

IT

X12

OR UN

/2

DO

 

 

**BLK

**YEL

**WH

**OR

**RED

 

**GREEN

 

1

 

 

1

 

1 FAN

2 RVS

3COMP1

4HLTV

5

+30 VDC

6DCRTN

TB

 

 

 

 

J1

1

3

 

4

 

 

 

RelayBoard

 

 

 

FAN

HLTV 2 RVS

 

COMP1

 

DCRTN

5

 

TAC673

 

 

 

 

 

K4

 

 

 

K3

 

 

 

K2

K1

COMP 1

1

 

TB1

FAN

 

H.L.T.V

 

 

RVS

 

 

FUSE

6A

 

 

 

 

HLTV

BLK

 

 

 

 

 

 

BLK

 

 

BLK

BLK

EU LB*

 

 

 

 

 

 

 

 

 

 

 

TH3 RVS

BLK

 

 

GR/YEL

GR/YEL

 

 

 

 

 

 

GND

 

 

GR/YEL

 

 

 

 

 

 

DC RTN

1

 

 

GR/YEL

 

 

 

 

 

 

 

 

 

DC RTN

2

 

 

 

 

 

 

 

 

 

 

 

 

N

 

1

 

 

 

 

 

 

 

 

 

 

 

 

N

 

2

 

 

TH3

BLK

 

 

 

 

 

 

 

 

L1

 

1

 

 

 

 

M

BLDC MOTOR

 

 

 

 

 

 

 

***RED

 

1

 

 

 

 

 

Out(+)

 

 

 

 

 

 

DC

PH-AC

GREEN

GREEN

 

 

1

AC DC IN Out

RB*

 

CC 1

RB*

R

COMP.

***GR/YEL

 

 

 

 

S

 

 

 

 

 

KLB*

C

 

 

 

 

 

EULB*

 

 

 

*OR

 

 

 

 

 

 

 

 

CC - COMP- FC -Fan GND -Ground RVS - HLTV -Heating TB - BLDC - TH1 -Return TH2 -Indoor

TH3- Indoor-12-Indoor

 

DCRTN(-)

 

 

 

 

30VDC

PowerSupply

 

 

LEU BN

L1 BR

***GREEN

 

 

 

 

FC 1

 

 

 

 

T H W

654321

T H W

 

 

NRB

NRB

 

 

LEY / RG

DER

 

 

LEY / RG

 

 

 

 

 

KLB

KLB

 

 

WHT

 

 

 

 

TH W

 

 

FAN MOTOR

FAN MOTOR

FAN COIL WITH DFC2H318J2A, DFC2H318J2A

09

UT

X

O

Models2

 

BLK

2

R UNIT

TH3

DOO

TH2

IN

TH1

 

 

 

 

 

 

 

 

 

 

L1

2

 

 

RVS

BLK

 

BLK

 

*BLUE

 

 

 

 

TB

 

 

 

 

 

 

 

 

 

 

 

 

 

EULB*

 

 

 

 

 

 

 

 

 

2

 

KLB*

 

 

 

 

 

HLTV

 

 

 

 

 

 

 

 

 

 

 

 

 

CC

 

 

RB*

 

 

 

 

 

BLK

 

 

 

RB*

 

 

 

 

 

 

 

 

 

 

 

2

 

TB1

 

 

FAN

H.L.T.V

RVS

 

 

FUSE

6A

 

 

 

 

 

 

K4

 

K3

 

 

K2

K1

COMP 1

 

 

 

 

FAN

HLTV

RVS

COMP1 DCRTN

 

673

Board

 

 

 

J1

1

2

3

4

5

 

TAC

Relay

 

2

 

1

 

2 3 4 5 6

TB 2

 

 

 

 

 

FAN

 

RVS

COMP 1

HLTV

+30VDC**GREEN

DC RTN

 

 

 

 

**BLK

**YEL

**WH

**OR

**RED

 

 

 

TB

1 2 3

 

5

 

 

 

 

 

 

BLK

YEL

WH

OR

4RED GREEN

6 GR/YEL

GND

 

 

 

 

 

 

FAN

 

H.L.T.V

RVS

COMP.

 

 

 

 

 

 

 

 

5

4

 

3

2

 

 

 

J8

 

J18

K6

 

K5

 

1K

 

K2

 

J6J7

 

 

 

 

 

 

 

 

 

 

 

COMP.

*OR

 

 

***GR/YEL

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N BLUE

L1 BR

***GREEN

PH-AC

 

 

 

 

GREEN

GREEN

 

*BR

*BR

*BLUE

 

*BLUE

*GR/YEL

 

2

DC AC Out IN

 

30VDC

PowerSupply

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

Out(+)

 

RTN(-)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC

 

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

***RED

 

 

 

 

 

 

 

BLDC MOTOR

 

 

 

L1

 

 

N

 

 

GND

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J1132

RED +30VDC

 

BLK DCRTN

YEL VSP

WHT+12VDC

 

1 6

 

 

 

 

J3

TAC672B

MotorControl

 

 

 

 

1

3

J5

3

4

5

2

3

4

5

 

 

 

 

 

1

 

2

 

 

 

 

J4

 

 

 

 

 

 

 

 

 

 

+12VRED

-12VBLK

 

 

+30VWH

 

FAN1BLUE

2FAN

 

 

FAN3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

BLK

 

 

 

 

 

 

 

 

1STEPPER

 

 

 

1

 

5

4

 

6

671TACMain

Board

670TACcontrol

 

 

 

 

J12

MOTOR

J11

 

 

K8

 

K9

 

 

K7

 

 

 

 

J14

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KLB

LEY / RG

NRB

T H W 2

FC

LEGENDL1 N

56

KLB

34

RG/LEY

12

DER

NRB

 

T H W

115VAC

MainsACSupply

51302523981-A

Fig. 13 System Wiring Schematic DFF2HH09J1A, DFF2HH12J1A

9

Page 9
Image 9
ICP DAS USA DFS2H324J2A Condensing Unit, pump, WiringDiagramHeat, Models2, MainsACSupply, Indoor Un, Or Un, R Unit, 115VAC