STP Operation continued
Slug Removal

SINGLE CYCLE

The STP can be used to remove the slug without applying heat to the blades, if the insulation has already been severed.

This is accomplished by pressing “0” when the unit is in the “READY MODE”. The next cycle will run with zero heat and

act only as a slug removal machine. When this cycle is completed, the STP returns to the previous settings.

REPEATING CYCLE

When the heat value is set to “0” percent the unit will perform the slug removal cycle when activated. The unit remains in this mode until a non zero

heat value is selected.

Set Mode

Press PROGRAM/HIGH

Enter in the 3-digit security code

NOTE: All units are factory preset to a 3-digit

security code of 111. To make any changes

in the Program Mode the security code must be

entered.

• Press

1 - Test 2 - Set

3 - Mode Clear_Esc

Select [2] - Set

When CLEARis pressed during any branch of the program mode, the display returns to the beginning and no changes are made.

PRGM.
HIGH
Press
ENTER IN 3-DIGIT
SECURITY CODE
Press
PRESS FOR CHOICE
1-TEST 2-SET CLR-ESC
BATCH
ENTER
Enter Security Code
2 Key
1-Set strip length increment
2-Set security code
3-Units
4-Lock out
5-Count
1-Blade home
2-Grip home sensor
3-Grip back sensor
4-Trigger sensor
5-Wire out sensor
6-Sensor test off
Up
Up
Up
Down
Down
Down
Down
Up
1-Full cycle
2-Half cycle
3-Step manually
-Clockwise
-Counter clockwise
Up
Up
Up
Up
Down
Down
Down
Up
Up
Up
Down
Down
Down
Down
-Back
-Forward
Program
1-Test
2-Set
Main
Menu
1-Warning on
2-Warning off
3-Set limit
4-Clear count
2- Lock off
1- Lock on
2- Metric
1- English
0 Key
1 Key
2 Key
3 Key
4 Key
6 Key
5 Key
7 Key
3 Key 4 Key 5 Key
1 Key
0-Test the sensors
1-Air blast
2-Pull cylinder
3-Chute
6-Front grip
5-Rear grip
7-Wire gate
8-Blade rotation
10-Beeper
9-Strip position
11-Blade heat
4-Trigger
8 Key
9 Key
3 Key

This flow chart shows the sequence of functions in the program mode indicating the keys to

press and the display screens with available options. The test mode shows the options for

testing sensors and solenoids.