Indesit K 643 G/G manual Connecting the gas supply, Electrial connection, Replacing the fuse, Blue

Models: K 642 GS/G K 642R GS/G K 642 G/G K 643 G/G K 645 G/G K 647 GS/G K 6432 G/G K 645R G/G K 647R G/G

1 16
Download 16 pages 62.38 Kb
Page 5
Image 5
Connecting the gas supply

Important:makesurethesupplypressureconformswiththevalues showninthetableentitled“Caracteristicsoftheburnersandnozzles”.

When the cooker is installed between cabinets (recessed), the gas connection must be effected by an approved flexible hose with bayonet fitting (BS 669 Current Edition). The gas inlet for the cookers is a threaded G 1/2 gas female fitting.

Connecting the gas supply

To make the connection, a flexible hose should be used corresponding to the current gas regulations which are:

the hose must never be at any point in its lenght in contact with the “hot”parts of the cooker;

the hose must never be longer than 1,5 metre;

the hose must not be subject to any tension or torsional stress and it must not have any excessively narrow curves or bottlenecks;

thehosemustbeeasytoinspectalongitsentirelengthtocheck its condition;

the hose must always be in good condition, never attempt to repair.

Important: theinstallationmustcomplywithgassafety(installation and use) regulations 1984. In all cases for the above, by low, a qualified, corgi approved engineer must be called for installation.

Electrial connection

Power supply voltage and frequency:230-240V a.c.50 Hz.

Note: the supply cable must be positioned so that it never reaches atanypointatemperature50°Chigherthantheroomtemperature. The cable must be routed away from the rear vents. Should you require it, you may use a longer cable, however, you must ensure that the cable supplied with the appliance is replaced by one of the same specifications in accordance with current standards and legislation.

Your appliance is supplied with a 13 amp fused plug that can be plugged into a 13 amp socket for immediate use.Before using the appliance please read the instructions below.

WARNING -THIS APPLIANCE MUST BE EARTHED.

THEFOLLOWINGOPERATIONSSHOULDBECARRIEDOUT BY A QUALIFIED ELECTRICIAN.

Replacing the fuse:

When replacing a faulty fuse, a 13 amp ASTA approved fuse to BS 1362shouldalwaysbeused,andthefusecoverre-fitted.Ifthefuse coverislost,theplugmustnotbeuseduntilareplacementisobtained.

Replacement fuse covers:

If a replacement fuse cover is fitted, it must be of the correct colour asindicatedbythecolouredmarkingorthecolourthatisembossed in words on the base of the plug. Replacements can be obtained directly from your nearest Service Depot.

Removing the plug:

Ifyourappliancehasanon-rewireablemouldedplugandyoushould wish to remove it to add a cable extension or to re-route the mains cable through partitions, units etc., please ensure that either:

theplugisreplacedbyafused13ampre-wireableplugbearing

the BSI mark of approval.

or:

the mains cable is wired directly into a 13 amp cable outlet, controlled by a switch, (in compliance with BS 5733) which is accessible without moving the appliance.

Please note: for appliances with a rating greater than 13 amp (eg: electric hob, double ovens and freestanding electric cookers etc.)

the mains cable must be wired into a cooker output point with a rating of 45 amp.In this case the cable is not supplied.

Disposing of the plug:

Ensure that before disposing of the plug itself, you make the pins unusable so that it cannot be accidentally inserted into a socket. Instructions for connecting cable to an alternative plug:

Important: thewiresinthemainsleadarecolouredinaccordance with the following code:

Green &Yellow

- Earth

Blue

- Neutral

Brown

- Live

If the colours of the wires in the mains lead do not correspond with thecolouredmarkingsidentifyingtheterminalsinyourplug,proceed as follows:

Connect Green & Yellow wire to terminal marked “E” or

 

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

 

 

coloured Green or Green &Yellow.

Connect Brown wire to terminal marked“L”or coloured Red. Connect Blue wire to terminal marked “N” or coloured Black.

If a 13 amp plug (BS 1363) is used it must be fitted with a 13 amp fuse.A 15 amp plug must be protected by a 15 amp fuse, either in the plug or adaptor or at the distribution board. If you are in any doubtabouttheelectricalsupplytoyourmachine,consultaqualified electrician before use.

How to connect an alternative plug:

The wires in this mains lead are coloured in accordance with the

followingcode:

 

 

BLUE

NEUTRAL”(“N”)

BROWN

LIVE”(“L”)

GREEN ANDYELLOW

EARTH” (“E”)

 

 

 

 

 

GREEN &

 

 

 

YELLOW

 

 

 

BROWN

13 amp fuse

 

 

 

 

 

BLUE

CROSS-BAR

 

 

 

CORD GRIP

 

 

 

 

 

Disposing of the appliance

Whendisposingoftheappliancepleaseremovetheplugbycutting the mains cable as close as possible to the plug body and dispose of it as described above.

Adapting the cooker to different types of gas

In order to adapt the cooker to a different type of gas with respect to the gas for which it was produced (indicated on the label attached to the lid), follow these steps:

a)replace the hose holder mounted on the appliance with that supplied in the bag of “cooker accessories”.

Important: the hose holder for liquid gas is marked 8, the hose holder for methane gas is marked 13. Always fit the sealing gasket.

b)Replacing the burner nozzles on the hob:

remove the grids and slide the burners from their housings;

unscrew the nozzles using a 7 mm socket spanner, and replace them with nozzles for the new type of gas (see table 1 “Burner and nozzle characteristics”).

replace all the components by repeating the steps in reverse order.

5

Page 5
Image 5
Indesit K 643 G/G Connecting the gas supply, Electrial connection, Warning -This Appliance Must Be Earthed, Blue, Brown