DISPLACEMENT PER CYCLE

DISPLACEMENT PER CYCLE

 

 

 

 

 

 

Specific Gravity = 1.000

 

 

 

 

 

 

 

 

Models

Gallons

Ounces

in.#

cc

Liters

Grams

Kg

 

 

 

 

 

 

 

 

3/8" Non-MetallicPD03P-X-X

0.022

2.815

5.082

83

0.083

83

0.083

 

 

 

 

 

 

 

 

1/2" Non-Metallic Duck Bill − 66605X-0XX

0.032

4.095

7.392

121

0.121

121

0.121

 

 

 

 

 

 

 

 

1/2" − PD05P-X-X-B, PD05R-X-X-B

0.039

4.991

9.009

148

0.148

148

0.148

 

 

 

 

 

 

 

 

1/2" − 66605X-X, PD05P-X-X, PM05P-X-X-A02

0.040

5.119

9.240

151

0.151

151

0.151

 

 

 

 

 

 

 

 

1" Non-Metallic6661AX-X-C, 6661BX-X-C

0.170

21.756

39.270

643

0.643

643

0.643

 

 

 

 

 

 

 

 

1" Metallic − 66610X-X-C, 66611X-X-C, 66612X-X-C,

0.160

20.476

36.960

606

0.606

605

0.605

66613X-X-C

 

 

 

 

 

 

 

1-1/2" Non-Metallic6661TX-X-C,6661UX-X-C

0.670

85.743

154.770

2536

2.536

2534

2.534

 

 

 

 

 

 

 

 

1-1/2" Metallic − 66615X-X-C, 66616X-X-C, 66617X-

0.640

81.903

147.840

2422

2.422

2421

2.421

X-C, 66618X-X-C

 

 

 

 

 

 

 

2" Non-Metallic6662AX-X-C, 6662BX-X-C

0.720

92.141

166.320

2725

2.725

2723

2.723

 

 

 

 

 

 

 

 

2" Metallic − PD20A-X-X, PF20A-X-X, PM20A-X-X-A02

1.400

179.164

323.400

5299

5.299

5296

5.296

 

 

 

 

 

 

 

 

3" Metallic − PD30A-X-X-B, PM30A-X-X-B02

2.800

358.327

646.800

10,598

10.598

10,591

10.591

2 strokes per complete cycle - 1" metallic will displace 0.080 gallons per stroke.

COIL OPTIONS

Coil Number

50 / 60 Hz

DC

116218-31

12

 

 

 

 

116218-33

120

 

116218-35

240

 

 

 

 

116218-37

 

5

116218-38

24

12

 

 

 

116218-39

48

24

PN 97999-760

Page 4 of 4

67165-X

Page 4
Image 4
Ingersoll-Rand 67277-X, 67165-X, 67166-X manual Displacement Per Cycle, Coil Options

FAQ

What is the displacement per cycle?

The displacement per cycle refers to the volume of fluid that is moved by the pump during one complete cycle. It is an important factor in determining the pump's efficiency.

What are the coil options for these heat pump models?

The coil options include various configurations for different frequency options, as well as options for direct current (DC) power.

Where can I find more information about the specific gravity and displacement for each model?

You can refer to the detailed table provided in the official manual for Ingersoll-Rand heat pump models 67165-X, 67277-X, 67166-X.