Ingersoll-Rand PE10X-XXX-XXX-XXXX Leak Detection Diaphragm Failure Detector, General Description

Models: PE10X-XXX-XXX-XXXX PE15X-XXX-XXX-XXXX PE20X-XXX-XXX-XXXX PE30X-XXX-XXX-XXXX

1 16
Download 16 pages 34.85 Kb
Page 9
Image 9
LEAK DETECTION (DIAPHRAGM FAILURE DETECTOR)

LEAK DETECTION (DIAPHRAGM FAILURE DETECTOR)

GENERAL DESCRIPTION

An ARO® diaphragm pump equipped with the ARO Diaphragm Failure Detector warns of a diaphragm failure by sensing the presence of liquid in the air chamber of the pump. This system uses a liquid sensor in each of the two air cham- bers which will send an output signal when fluid is detected.

INSTALLATION AND WARNINGS

NOTE: ALL WIRING MUST COMPLYWITH ALL LOCAL AND / OR NATIONAL ELECTRICAL CODES.

Electrical codes that apply must be strictly adhered to; failure to do so may lead to shock hazard or serious injury.

Some local electrical codes may require the installation of rigid conduit.

The diaphragm failure detector components must be installed by a qualified electrician in compliance with all national, state and local codes and regulations to reduce the risk of electrical shock or other serious injury during installation and operation.

ARO is not responsible for accidents resulting from im- proper installation of components or hardware.

HAZARDOUS VOLTAGE. Do not attempt any service without disconnecting all electrical supply sources.

PArt list / PEXXX-XXX-XXX-XXEX, PEXXX-XXX-XXX-XXLX

283

Figure 7

LEAK DETECTION (DIAPHRAGM FAILURE DETECTOR) - PINOUT DESCRIPTIONS

 

96270-1 SENSOR PINOUTS

 

B

 

C

A

 

 

Pinout

Function

 

A

+24 VDC

 

B

Ground

 

C

Signal

 

TURCK (PICOFAST) Connector PSW 3M -*/S90

Figure 8

Page of 16

PEXXP-XXX-XXX-XXXX (en)