Integra PLA-50V1 instruction manual Command Reference List

Models: PLA-50V1

1 57
Download 57 pages 28.18 Kb
Page 47
Image 47

Command Reference List

 

 

CMD1

CMD2

LEN

01. Power ON

9FH

4EH

00H

 

 

 

 

 

02.

Power OFF

9FH

4FH

00H

 

 

 

 

 

03.

Input Switch Change

DFH

47H

01H

 

 

 

 

 

04.

VOLUME Gain Data

DFH

7FH

03H

 

 

 

 

 

05.

SCREEN MODE Select

DFH

51H

01H

 

 

 

 

 

06.

AUDIO Mute On

9FH

3EH

00H

 

 

 

 

 

07.

AUDIO Mute Off

9FH

3FH

00H

08.

OSM Select

DFH

58H

01H

 

 

 

 

 

09.

Color Gain Data

DFH

7FH

03H

 

 

 

 

 

10.

TINT Gain Data

DFH

7FH

03H

11.

SHARPNESS Gain Data

DFH

7FH

03H

 

 

 

 

 

12.

CONTRAST Gain Data

DFH

7FH

03H

 

 

 

 

 

13.

BRIGHT Gain Data

DFH

7FH

03H

 

 

 

 

 

14.

Input MODE Request

1FH

41H

00H

 

 

 

 

 

15.

RESET

1FH

54H

00H

 

 

 

 

 

16.

COLOR TEMP SELECT

DFH

00H

01H

 

 

 

 

 

17.

RED Gain Data

DFH

7FH

04H

 

 

 

 

 

18.

GREEN Gain Data

DFH

7FH

04H

 

 

 

 

 

19.

BLUE Gain Data

DFH

7FH

04H

 

 

 

 

 

20.

VIDEO ADJ Request

1FH

45H

00H

 

 

 

 

 

21.

Audio Select Set

DFH

70H

02H

 

 

 

 

 

22.

Audio Select Request

1FH

6FH

00H

 

 

 

 

 

23.

LONG LIFE Set

DFH

6BH

03H

 

 

 

 

 

24.

Failure Mode Request

1FH

3FH

00H

 

 

 

 

 

01. Power ON

Function

The external control equipment switches on the power of the plasma monitor.

Transmission Data

9FH 80H 60H 4EH 00H CKS

ACK

The plasma monitor returns the following ACK when the power is switched on. 3FH 60H 80H 4EH 00H CKS

03. Input Switch Change

Function

The external control equipment switches the input of the plasma monitor.

Transmission Data

DFH

80H 60H 47H

01H DATA00

CKS

DATA00

: Input Select

01H: Video1

 

 

 

02H: Video2

 

 

 

03H: Video3

 

 

 

05H: HD (HD1 or DTV or DTV1)

06H: HD2 (DTV2)

07H: RGB1/PC1

08H: RGB2/PC2

0CH: RGB3/PC3

ACK

The plasma monitor returns the following ACK when the input is switched.

3FH 60H 80H 47H 00H CKS

04. VOLUME Gain Data

Function

The external control equipment changes the VOLUME gain data of the plasma monitor.

Transmission Data

 

 

DFH 80H 60H 7FH 03H

DATA00 DATA01 DATA02 CKS

DATA00

USER SOUND Gain Flag

05H

DATA01

VOLUME Gain Flag

01H

DATA02

VOLUME Gain

00H: Step 0

 

 

 

 

 

 

0AH: Step 10 (Default)

 

 

 

 

 

 

2AH: Step 42

ACK

 

 

 

 

 

7FH 60H 80H 7FH 02H

DATA00 DATA01 CKS

DATA00 USER SOUND Gain Flag

05H

DATA01 VOLUME Gain Flag

01H

NOTE: Do not set the Power ON or Power OFF command continuously.

02. Power OFF

Function

The external control equipment switches off the power of the plasma monitor.

Transmission Data

9FH 80H 60H 4FH 00H CKS

ACK

The plasma monitor returns the following ACK when the power is switched off. 3FH 60H 80H 4FH 00H CKS

NOTE: Do not set the Power ON or Power OFF command continuously.

05. SCREEN MODE Select

Function

The external control equipment switches the screen mode of the plasma monitor.

Transmission Data

DFH 80H 60H 51H 01H DATA00

CKS

DATA00 02H : STADIUM 03H : ZOOM

04H : NORMAL

05H : FULL

06H : TRUE (REAL)

ACK

7FH 60H 80H 51H 01H DATA00

CKS

DATA00 02H : STADIUM 03H : ZOOM

04H : NORMAL

05H : FULL

4106H : TRUE (REAL)

Page 47
Image 47