Intel SR1450 manual Replacing the Hot-SwapPower Supply, Removing a Hot-SwapPower Supply

Models: SR1450

1 87
Download 87 pages 48.32 Kb
Page 61
Image 61
Replacing the Hot-Swap Power Supply

Hardware Installations and Upgrades

Replacing the Hot-Swap Power Supply

The power supply can be replaced if it fails. If your server uses a redundant power supply, you do not need to power down your server to replace the failed power supply, as long as the remaining power supply is plugged into an AC power source and is functioning. If you do not have a redundant power supply installed, you must power down your server system before replacing the power supply.

NOTE

Power supply receptacles are dedicated to the front and back power supplies. Make sure AC power is plugged in correctly to ensure the power supply functions.

Removing a Hot-Swap Power Supply

To replace the power supply, use the following instructions.

1.(Non-redundant power supply only) Power down the server.

2.Remove the AC power cable from the inlet connector on the failed power supply.

3.Open handle, push the green latch toward the right (see letter “A” in the figure below), and pull the power supply out of the chassis (see letter “B” in the figure below).

A

B

TP01622

Figure 45. Removing the Front Hot-Swap Power Supply from the Chassis

Intel® Server Chassis SR1450 User Guide

61

Page 61
Image 61
Intel SR1450 manual Replacing the Hot-SwapPower Supply, Removing a Hot-SwapPower Supply