TFX12V Power Supply Design Guide
Thin Form Factor with 12 V Connector
Version 2.0
2 Electrical
The following electrical requirements must be met over the environmental ranges as defined in Section 5 (unless otherwise noted).
2.1 AC Input
Table 1, lists AC input voltage and frequency requirements for continuous operation. The power supply shall be capable of supplying
Table 1. AC Input Line Requirements
Parameter | Minimum | Nominal* | Maximum | |
Vin | (115 VAC) | 90 | 115 | 135 |
Vin | (230 VAC) | 180 | 230 | 265 |
Vin | Frequency | 47 | 63 |
*Note: Nominal voltages for test purposes are considered to be within ±1.0 V of nominal.
Unit
VAC rms
VAC rms
Hz
2.1.1Input Over Current Protection
The power supply shall incorporate primary fusing for input over current protection to prevent damage to the power supply and meet product safety requirements. Fuses should be
2.1.2Inrush Current Limiting
Maximum inrush current from
2.1.3Input Under Voltage
The power supply shall contain protection circuitry such that the application of an input voltage below the minimum specified in Section 2.1, Table 1, shall not cause damage to the power supply.
1For Denmark and Switzerland international safety requirements, if the internal over current protective devices exceed 8A for Denmark and 10A for Switzerland, then the power supply must pass international safety testing to EN 60950 using a maximum 16A
10