2.2.5.1Energy Star*
The “Energy Star” efficiency requirements of the power supply depend on the intended system configuration. In the low power / sleep state (S1 or S3) the system should consume power in accordance with the values listed in Table 9.
Table 9. Energy Star Input Power Consumption
Maximum Continuous Power Rating of
Power Supply
< 200 W
>200 W < 300 W
>300 W < 350 W
>350 W < 400 W > 400 W
RMS Watts from the AC Line in Sleep/low-Power
Mode
<15 W
<20 W
<25 W
<30 W
10% of the maximum continuous output rating
Note: To help meet the “Energy Star” system requirements, it is recommended that the power supply have > 50% efficiency in standby mode.
2.2.6Other Low Power System Requirements
To help meet the Blue Angel* system requirements,
2.2.7Output Ripple/Noise
The output ripple/noise requirements listed in Table 10 should be met throughout the load ranges specified in Section 2.2.3 and under all input voltage conditions as specified in Section 3.1.
Ripple and noise are defined as periodic or random signals over a frequency band of 10 Hz to 20 MHz. Measurements shall be made with an oscilloscope with 20 MHz of bandwidth. Outputs should be bypassed at the connector with a 0.1µF ceramic disk capacitor and a 10µF electrolytic capacitor to simulate system loading. See Figure 6.
Table 10. DC Output Noise/Ripple
Output
+12 V1DC
+12 V2DC
+5 VDC
+3.3 VDC
+5 VSB
Maximum Ripple and Noise
(mVpp)
120
200
50
50
120
50