Intel TFX12V Efficiency Vs Load, Loading Table for Efficiency Measurements, Full load, Light load

Models: TFX12V

1 40
Download 40 pages 41.31 Kb
Page 17
Image 17
Table 7: Efficiency Vs Load

TFX12V Power Supply Design Guide

Thin Form Factor with 12-V Connector

Version 2.0

115VAC input and 230VAC input, under the load conditions defined Table 8, and under the temperature and operating conditions defined in Section 3. The loading condition for testing efficiency shown in Table 7 represents a fully loaded system, a typical (50%) loaded system, and a light (20%) loaded system.

Table 7: Efficiency Vs Load

Loading

Required Minimum Efficiency

Recommended Minimum Efficiency

Full load

70%

75%

Typical load

70%

80%

Light load

60%

68%

Table 8. Loading Table for Efficiency Measurements

180W (loading shown in Amps)

Loading

+12V

+5V

+3.3V

-12V

+5Vsb

Full

11

4

5.8

0.3

1.0

Typical

7

3

4

0.1

1.0

Light

2

0.3

0.5

0.0

 

 

 

1.0

220W (loading shown in Amps)

Loading

+12V

+5V

+3.3V

-12V

+5Vsb

Full

13

5

9

0.3

1.0

Typical

8

3

5

0.1

1.0

Light

3

0.5

2.0

0.0

1.0

240W (loading shown in Amps)

Loading

+12V

+5V

+3.3V

-12V

+5Vsb

Full

14.5

7

7

0.2

1.0

Typical

7

4

5

0.1

1.0

Light

3.4

1.0

3.0

0.0

1.0

270W (loading shown in Amps)

Loading

+12V1

+12V2

+5V

+3.3V

-12V

+5Vsb

Full

4

11.5

9.4

9

0.2

1.0

Typical

2

5.5

4.5

4

0.1

1.0

Light

1

2.4

0.4

0.7

0.0

1.0

Page 17
Image 17
Intel TFX12V Efficiency Vs Load, Loading Table for Efficiency Measurements, Full load, Typical load, Light load, +12V