Installing Microsoft Windows 2000 or Windows NT 4.0 on an Intel Integrated RAID Volume

1Create a SRCU31L Microsoft Windows 2000 or Windows NT Installation Driver (temporary) Diskette

a.Insert the SRCU31L Software CD-ROM into the target system and restart the system to boot from the CD-ROM.

b.When the ROM-DOS Startup Menu appears select option #1, Make Diskettes.

c.When the Select a diskette to create screen appears, select Windows NT Installation for Windows NT 4.0 or Windows 2000 Installation for Windows 2000. A command window appears.

d.Insert a blank high-density diskette in drive A: and press Enter to create the Windows Installation Driver Diskette.

2Install Microsoft Windows 2000 or Windows NT 4.0

a.Boot with the Windows 2000 or Windows NT 4.0 CD-ROM.

b.Press F6 as soon as the first blue screen appears to ensure that Windows Setup bypasses mass storage controller detection.

c.When prompted to specify a mass storage controller:

Select S to specify additional storage devices.

Insert the appropriate SRCU31L Microsoft Windows Installation Driver Diskette (created in Step 1 above) in the floppy drive and press Enter.

Press Enter to select the Installation Driver and continue with Windows installation (see example for Windows 2000 below).

Windows 2000 Setup Screen Example

10

Intel Server RAID Controller U3-1L (SRCU31L)

 

Quick Start Guide