________________________3

The ITI-5100G/GF Driver Software

A network device driver must be installed before the ITI-5100G/GF adapter can be used with your systems. This chapter describes how to preform the following tasks:

￿￿Install the driver software in the Solaris environment

￿￿Configure the host files

￿￿Configure driver parameters using the ndd utility

Installing the Driver Software

Note: The ITI-5100G/GF adapter must be physically installed in your server prior to installing the driver software. See “Installing the ITI- 5100G-GF Hardware,” for details.

To install the adapter software for Solaris, perform the following procedure:

1.Become superuser (root).

2.Note the revision level of the Software Distribution Media included with your IntraServer Technology adapter.

The revision level is stamped on the Software Distribution Media label and is used in the commands below.

Place the Software Distribution Media into the CD-ROM drive.

Mount the CD-ROM on a local directory.

￿￿If the Volume manager (vold) is running on your machine, when the ITI-5100G/GF CD-ROM is loaded into the drive, it is mounted automatically under /cdrom/cdrom0

#volcheck

Access the package directory by entering the following:

# cd /cdrom/cdrom0

LSI Logic Corporation