Tumblers – T30 and T45

Electrical Requirements for Electric Models

Refer to Table 6.

NOTE: Minimum wire sizes are obtained from Canadian Electrical Code for 75°C Conductors and are intended for use as a guideline only.

Electrical connections should be made only by a qualified electrical contractor in accordance with all applicable local and national requirements.

For 21 kW T30 Electric Models:

NOTE: Electrical specifications below are subject to change without notice. Always refer to product serial plate for most current specifications of product being installed.

NOTE: Connect to individual branch circuit.

NOTE: 3 Phase Only – Each tumbler must be connected to its own individual branch circuit breaker, not fuses, to avoid the possibility of “single phasing” and causing premature failure of the motor(s).

 

Terminal Block

 

Recommended

 

Recommended

Serial Plate

Current

Breaker

Minimum

Connections

Breaker Rating

Voltage

(Amps)

Poles

Conductor Size

 

Required

 

(Amps)

 

(AWG [mm2])

200-208V/60Hz/3ph*

L1, L2, L3,

62**

80

3

4 (21.2)

and ground

 

 

 

 

 

 

 

 

 

200V/50Hz/3ph*

L1, L2, L3,

60**

80

3

4 (21.2)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230-240V/50Hz/3ph*

L1, L2, L3,

55**

70

3

4 (21.2)

and ground

 

 

 

 

 

 

 

 

 

240V/60Hz/3ph*

L1, L2, L3,

54**

70

3

4 (21.2)

and ground

 

 

 

 

 

 

 

 

 

380V/50 or 60Hz/3ph*

L1, L2, L3,

33**

45

3

8 (8.37)

and ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400-415V/50Hz/3ph*

L1, L2, L3,

31**

40

3

8 (8.37)

and ground

 

 

 

 

 

 

 

 

 

460-480V/60Hz/3ph*

L1, L2, L3,

27**

35

3

8 (8.37)

and ground

 

 

 

 

 

 

 

 

 

*These serial plate voltages are only options available on the T30 electric models. Current (Amp) is for one pocket only.

**Per heater on T30 electric models, each has two heaters.

Table 6

4-08-43

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

20

Page 21
Image 21
IPSO T30, T45 Electrical Requirements for Electric Models, Terminal Block Recommended, Current Breaker Minimum Connections