Tumblers – T30 and T45

For T45 Gas Models (For Total Machine):

 

Terminal Block

 

 

Recommended Fuse

 

Recommended

Serial Plate

Current

 

Breaker

Minimum

Voltage

Connections

(Amps)

 

or Breaker Rating

Poles

Conductor Size

Required

 

(Amps)

(AWG [mm2])

 

 

 

 

 

 

 

208–240V/60Hz/1ph

L1, L2, Neutral and ground

12.0

 

15

2

14 (2.08)

 

 

 

 

 

 

 

200–208V/60Hz/3ph

L1, L2, L3 and ground

9.6

 

15

3

14 (2.08)

 

 

 

 

 

 

 

240V/60Hz/3ph

L1, L2, L3 and ground

9.6

 

15

3

14 (2.08)

 

 

 

 

 

 

 

200V/50Hz/1ph

L1, Neutral and ground

11.2

 

15

1

14 (2.08)

 

 

 

 

 

 

 

230-240V/50Hz/1ph

L1, Neutral and ground

10.8

 

15

1

14 (2.08)

 

 

 

 

 

 

 

 

 

Table 5

 

 

 

19

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

4-08-43

Page 20
Image 20
IPSO T45, T30 Terminal Block Recommended Fuse, Current, Minimum, Connections Amps Or Breaker Rating Poles Conductor Size