SECTION 5: SERVICE PROCEDURES

REPLACING THE CHEMICAL FEEDER PUMP MOTOR (CONTINUED)

replaced. Refer to the parts section of the technical manual for information regarding part numbers for ordering new prime switches.)

6.Turn the cover over and using the phillipshead screwdriver, remove the cover to the pump requiring a motor change.

Removing the priming switch wire

Unhooking motor power wire

Removing the pump front cover screws.

Removing the front cover.

7.With the cover removed, gently pull out the rubber tube from inside the pump.

Pulling the rubber tube out of the pump.

8.Remove the roller by pulling it off of the shaft.

9.Using the phillipshead screwdriver, remove the four mount- ing screws for the motor.

10.Once the screws are removed, the motor should drop away.

11.Cut away any tie-wraps that are holding the power wires and remove the motor.

12.Take your new motor and attach new terminals to the wires as required.

13.Remount the motor to the pump.

Delta 1200 Technical Manual 07610-003-62-15 G

Issued: 10-27-2008 Revised:05-21-2012

18

Page 23
Image 23
Jackson Chemical Sanitizing Glasswasher Dishmachine Series, Delta 1200 Pulling the rubber tube out of the pump