SECTION 5: SERVICE PROCEDURES

WASH MOTOR REPLACEMENT (CONTINUED)

Position the assembly so that the suction hose is not kinked.

21.Replace and tightne down the nuts securing the bracket to the frame.

22.Tighten the clamps for the suction hose.

23.Connect the disharge hose to the tub and tighten down the hose clamp.

AFTER MAINTENANCE ACTIONS

Verify the operation of the new wash motor and pump assembly by running the unit for approximately 15 min- utes. Check for leaks and corredt as necessary.

SPECIAL NOTES

Work performed on Jackson dishmachines by unau- thorized or unqualified personnel may void the warranty. Before beginning this or any other maintenance evolution on a unit under warranty, you should contact a certified Jackson technician or Jackson Technical Service. You can find a list of qualified service agencies in the back of you unit’s installation manual.

SPECIAL PARTS

Delta 1200 Technical Manual 07610-003-62-15 G

Issued: 10-27-2008 Revised:05-21-2012

27

Page 32
Image 32
Jackson Delta 1200, Chemical Sanitizing Glasswasher Dishmachine Series technical manual After Maintenance Actions