SECTION 1: SPECIFICATION INFORMATION
SPECIFICATIONS
Delta 1200 |
|
OPERATING CAPACITY (RACKS/HOUR) |
|
GLASSES PER HOUR | 1200 |
OPERATING CYCLE (SECONDS) |
|
TOTAL CYCLE TIME | 120 |
TANK CAPACITY (GALLONS) | 3.0 |
WASH PUMP CAPACITY |
|
WASH PUMP | 55 GPM |
TEMPERATURES |
|
130 | |
75 | |
ELECTRICAL REQUIREMENTS |
|
WASH PUMP MOTOR HORSEPOWER | 1/10 |
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed- trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all applicable national and local codes. These numbers are provided in this manual simply for reference and may change without notice at any given time.
|
|
| RINSE |
| TYPICAL |
|
|
| HEATER | TOTAL | ELECTRICAL |
VOLTS | PH | HZ | RATINGS | AMPS | CIRCUIT |
208 | 1 | 60 | 220V/3KW | 15A | 15A |
230 | 1 | 60 | 220V/3KW | 15A | 15A |
WATER REQUIREMENTS |
|
| |||
INLET TEMPERATURE |
| 130°F | |||
GALLONS PER HOUR |
| 10.0 | |||
WATER LINE SIZE NPT (Minimum) |
| 1/2” | |||
DRAIN LINE SIZE NPT (Minimum) |
| ||||
FLOW PRESSURE P.S.I. |
| 205 | |||
MINIMUM CHLORINE REQUIRED (PPM) | 50 | ||||
MINIMUM IODIPHOR REQUIRED (PPM) | 12.5 |
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.
Delta 1200 Technical Manual