Page 16
J-400 Series
7.0 Power requirements
Jacuzzi® spas are designed to provide optimum performance and
exibility of use when connected to their maximum electrical service.
They are congured at the factory. The most common electrical
connections are listed below:
all north american 60 Hz models only: These models come set for
50A logic. If you prefer, your qualied technician can perform a logic
modication that allows the spas to operate on a different electrical
service (see table footnotes below).
north american J-460/J-465/J-470/J-480 models (60 Hz)
Voltage: 240 VAC 240 VAC 240 VAC
Max. Current Draw: 23A 36A 45A
Frequency: 60 Hz 60 Hz 60 Hz
Number of Wires: 333
Circuit Breaker (2-Pole): 30A*50A** 60A***
* In 30A conguration, the heater will not operate while either jets
pump is running.
** In 50A conguration, the heater will not operate while both jet
pumps are running. This is the factory setting.
*** In 60A conguration the heater will operate while both jet pumps
are running.
all export 50 Hz models: These models have two terminals
requiring 2 circuit breakers and only have one logic option available.
export J-460/J-465/J-470/J-480 models (50 Hz)
Main
Terminal Breaker*
Heater
Terminal Breaker**
Voltage: 230 VAC 230 VAC
Max. Current Draw: 16.6A 12A
Wattage 3.8 kW 2.6 kW
Frequency: 50 Hz 50 Hz
Number of Wires: 3 3
* The main terminal breaker is solely for the pumps, circulation
pump, ozone, stereo option (if installed) and accessories.
** The heater breaker is solely for the heater, to allow the heater to
operate while both jet pumps are running.
note: Two breakers needed see Figure e page 14.