CV-A33CL

When( the exposure ism in . (PE=2))

TRG

 

 

1 FVAL per iod

2L

502L

498L

 

FVAL

LVAL

27 .6 μS

Exposure per iod

EEN

E f fec t ive L ines 493L

DATAOUT

0 1 2 3 4 ……

……

 

 

DVAL

1 LVAL = 16.825s

2L

5L

4

8

8

4

8

9

4

9

0

4

9

1

4

9

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 20. Vertical timing for edge pre-select min. exposure

When( the exposure ismax . (PE=493))

 

 

 

 

 

 

 

 

1 LVAL = 16.825s

TRG

 

 

 

1 FVAL per iod

 

 

 

 

 

 

 

2L

 

502L

 

2L

 

498L

 

 

 

 

 

 

 

FVAL

LVAL

27 .6 μS

Exposure per iod

EEN

DATAOUT

DVAL

0 1 2 3 4 ……

E f fec t ive L ines 493L

……

5L

4

8

8

4

8

9

4

9

0

4

9

1

4

9

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 21. Vertical timing for edge pre-select max. exposure

- 15 -

Page 16
Image 16
JAI CV-A33CL operation manual Vertical timing for edge pre-select min. exposure