CV-A33CL

7.3. CV-A33CL command list

Command Name

Format

A – General settings and useful commands

Parameter

Remarks

 

EB

 

Echo Back

[

 

 

 

]

 

 

 

0=Echo off

1=Echo on

Off at power up

 

 

EB= Param. <CR><LF>

 

 

ST

 

Camera Status request

ST?<CR><LF>

 

 

 

 

Actual setting

 

HP

 

Online Help request

HP?<CR><LF>

 

 

 

Command list

 

VN

 

Firmware version

VN?<CR><LF>

 

 

 

3 letter version

 

ID

 

Camera ID request

ID?<CR><LF>

 

 

 

 

10 characters

 

MD

 

Model Name request

MD?<CR><LF>

 

 

 

10 characters

 

UD

 

User ID (Free text)

TR=[Param.]<CR><LF>

User can save and load free text

16 characters

 

 

B –

Video Output

 

 

 

 

 

 

 

 

 

 

 

 

BA

 

Output bit allocation

BA=[Param.]<CR><LF>

0=10 bit

1=8 bit

Camera Link

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C –

Timing and shutter related

commands

 

 

 

 

 

 

 

 

WS

 

Windows Scan

WS=[Param.]<CR><LF>

0=full frame

1=windows scan

 

 

WX

 

X Scan start coordinate

WX=[Param.]<CR><LF>

0-657

 

Start pixel #

 

WY

 

Y Scan start coordinate

 

[

 

]

<CR><LF>

0-490

 

Start line#

 

 

WY= Param.

 

 

 

 

WW

 

X Scan size width

 

 

[

 

]

<CR><LF>

2-659

 

Window width

 

 

WW= Param.

 

 

 

 

WH

 

Y Scan size height

 

 

[

 

 

]

 

3 – 493

 

Window height

 

 

WH=

Param. <CR><LF>

 

 

 

AT

 

Auto Trigger

AT=[Param.]<CR><LF>

3-493

 

*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wind. 3H to 493H

 

TR

 

Trigger mode

TR=[Param.]<CR><LF>

0=normal

1=Edge pre-sel

 

 

 

 

 

 

 

 

 

 

 

 

 

2=Pulse width

3=Auto Trigger

 

 

SM

 

Shutter mode

SM=[Param.]<CR><LF>

0=Normal

1=Program. exp

 

 

SH

 

Shutter speed

SH=[Param.]<CR><LF>

0=Off (1/120)

1=1/250

All 8 steps are

 

 

 

 

 

 

 

 

 

 

 

 

2=1/500

3=1/1000

valid in normal

 

 

 

 

 

 

 

 

 

 

 

 

4=1/2000

5=1/5000

trigger mode.

 

 

 

 

 

 

 

 

 

 

 

 

6=1/10000

7=1/20000

 

 

PE

 

Programmable expos.

[

 

 

 

]

 

 

 

2-493

 

Exp. 1H to 492H

 

 

PE=

Param. <CR><LF>

 

H= 16.8sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D–

Signals and polarity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LS

 

LVAL synchronous accum.

[

 

 

 

]

 

 

 

0= LVAL sync.

1= LVAL a-sync.

*1) Only a-sync.

 

 

LS=

Param. <CR><LF>

 

 

TI

 

Trigger Input

TI=[Param.]<CR><LF>

0= CamerLink

1= 12 pin Hiror

 

 

 

 

 

[

 

]

 

 

 

 

 

*2)

 

TP

 

Trigger polarity

TP= Param.

<CR><LF>

0= active low

1= active high

 

 

E –

Gain and analogue signals setting

 

 

 

 

 

 

 

 

 

 

 

BL

 

Black level

BL=[Param.]<CR><LF>

0-31(0=low 31=high)

 

 

 

 

 

 

 

 

 

GA

 

Gain level

GA=[Param.]<CR><LF>

1-11(0=low 11=high)

 

 

CB

 

Calibration of CMOS sensor

CB=0<CR><LF>

0 is the only allowed parameter

Will calibrate the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CMOS sensor

 

F –

Saving and loading data in EEPROM

 

 

 

 

 

 

 

 

 

LD

 

Load settings from camera

[

 

 

]

 

 

 

0=Factory data

1=User 1 area

Latest used data

 

 

LD=

 

Param. <CR><LF>

default at power

 

 

 

EEPROM

 

 

 

 

 

 

 

 

2=User 2 area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

up

 

SA

 

Save settings to camera

SA=[Param.]<CR><LF>

1=User 1 area

2=User 2 area

Parameter = 0 is

 

 

 

EEPROM

 

 

 

 

 

 

 

 

 

 

not allowed

*)

 

Auto trigger window will always

start from top. Max frame rate

with AT=3. It is 2 LVAL exposure + 9 LVAL

offset.

*1)

 

The command LS is found on the first cameras. Only LS=1 is will work correct.

 

 

*2)

 

If positive logic is used (TP=1), the first trigger pulse after power up will be ignored. TTL only.

 

!!Do not try to use commands not shown in this list.

- 20 -

Page 21
Image 21
JAI operation manual CV-A33CL command list, Parameter Remarks