7.2. RS-232C control

All configuration of the CV-A33CL camera is done via the RS-232C port on the 12 pin HR connector or via Camera Link. (Internal switch SW200 off for HR). The camera can be set up from a PC running terminal emulator software, or using JAIĀ“s camera control software. Below is the description of the ASCII based short command protocol.

Communication setting.

 

Baud Rate

9600 bps

 

 

 

 

 

 

 

1 CD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 DTR

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Length

8 bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 DSR

9 pin

 

 

 

 

 

 

 

 

 

Start Bit

1 bit

 

CAMERA

TXD

 

 

 

 

2 RXD

D-con

 

 

 

 

 

 

 

 

 

RS 232C cable

RXD

 

 

 

3 TXD

PC COM

 

Stop Bit

1 bit

 

 

 

 

 

GND

 

 

5 GND

 

 

 

 

 

 

 

PORT

 

 

 

 

 

 

Parity

None

 

 

 

 

 

 

 

7 RTS

 

 

 

 

 

 

 

 

 

 

 

8 CTS

 

 

Xon/Xoff Control

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 CI

 

Protocol.

 

 

 

 

 

 

 

 

 

 

Transmit setting to camera:

NN=[Parameter]<CR><LF> (NN is any kind of command. Capital or small letters.) The camera answers:

COMPLETE<CR><LF>

To have all communication visible on the emulator screen, start with:

EB=1<CR><LF>

The camera answers:

COMPLETE<CR><LF>

Transmit request command to camera:

NN?<CR><LF> (NN is any kind of command.)

The camera answers:

NN=[Parameter]<CR><LF>

Transmit the following to have the camera actual setting:

ST?<CR><LF>

The camera answers:

A complete list of the current settings

Transmit the following to have a command list:

HP?<CR><LF>

The camera answers:

A list with all commands and possible settings

Invalid parameters send to camera: (99 is an invalid parameter)

SH=99<CR><LF>

The camera answers:

02 Bad Parameters!!<CR><LF>

To see firmware number.

VN?<CR><LF>

To see camera ID. It shows the manufacturing lot number.

ID?<CR><LF>

- 19 -

Page 20
Image 20
JAI CV-A33CL operation manual RS-232C control