CV-M91

- 24 -

9.2. Specification table
Specifications CV-M91P CV-M91N
Scanning system
CCIR PAL, 25 frames/sec.
625 lines, 2:1 Interlaced
EIA NTSC. 30 frames/sec.
525 lines, 2:1 Interlaced
Frame rate 50 Hz 59.94 Hz
Line frequency 15.625 kHz 15.734 kHz
Pixel frequency 14.25 MHz 14.349949 MHz
CCD sensors 3 x 1/3” monochrome IT CCD
ICX-409AL-6
3 x 1/3” monochrome IT CCD
ICX-408AL-6
Sensing area 4.8 (h) x 3.6 (v) mm
Effective pixels 752 (h) x 582 (v) 768 (h) x 494 (v)
Pixels in video output 744 (h) x 575 (v) 765 (h) x 486 (v)
Cell size 6.5 (h) x 6.25 (v) µm 6.35 (h) x 7.4 (v) µm
Resolution horizontal 570 TV lines
Sensitivity (on sensor) 0.5 Lux, Max gain, 50% video
S/N ratio 54 dB 56 dB
Video outputs. (DC coupled) RGB
Y/C PAL
VBS PAL
RGB
Y/C NTSC
VBS NTSC
Video output level RGB and C signal, 0.7 Vpp, 75
G on sync, Y signal and Composite VS, 1.0 Vpp, 75
Gamma 1.0 - 0.45
Gain
Gain range
Manual – Automatic
0 to +18 dB
Accumulation Field – Frame
Synchronization Int. X-tal. Ext HD/VD or random trigger
Scanning 2:1 interlaced, non-interlaced
Composite VS input 1.0 Vpp ±0.3V. 75 terminated
Composite sync output 4 Vpp from 75 source
HD/VD sync input 4 Vpp ±2 V. (Termination TTL or 75 )
HD/VD sync output 4 Vpp from 75 source
Trigger input 4 Vpp ±2 V. (Termination TTL or 75 )
WEN output (write enable) 4 Vpp from 75 source
EEN output (exposure enable) 4 Vpp from 75 source
Pixel clock output 4 Vpp from 75 source
Shutter.
Continuous and Edge pre-select
(off), 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10,000 sec.
Pulse width control input 1 H to 900 H
Start/stop 1/10,000 to 1/77 second
Long time exposure 1 field to
White balance Manual, one push (2350 to 6400 K)
Functions controlled by
RS 232C
Trigger mode, Shutter speed, Accumulation, Interlace, AGC level, White clip,
Set-up, Manual gain, AGC/manual gain, Internal/ potentiometer gain set,
Gamma, white balance.
Functions controlled by internal DIP
switches
VD input/output, HD input/output
HD, VD and Trigger 75 termination on/off
Operating temperature -5°C to +45°C.
Humidity 20 - 80% non-condensing
Storage temp./humidity -25°C to 60°C./20% - 90 % non-condensing
Vibration 3 G (15 Hz – 200 Hz in XYZ)
Shock 50 G
Regulations CE (EN 50081-1, EN 50082-1) FCC part 15
Power 12V DC ± 10%. 6 W
Lens mount C-mount. (Max 4.0 mm thread)
Dimensions 50 x 60 x 130 mm (HxWxD)
Weight 480 g