INSTALLATION7

CONVERTIBLE OPTIONS

This range hood is equipped with the option of a 6” vertical discharge, 3 1/4”x10” vertical discharge, or 3 1/4”x10” rear discharge. Additional accessories are provided to convert to either of the above discharge methods.

Convertible Options

 

 

Convertible Accesories

 

Vertical discharge

6” round

 

Round to rectangular transition adaptor

 

Vertical discharge

3 1/4”x10”

 

Rectangular to round transition adaptor (pre-mounted)

 

 

 

 

 

Horizontal rear discharge

3 1/4”x10”

 

Gasket (pre-mounted)

 

 

 

 

 

 

 

 

Rectangular rear cap (pre-mounted)

 

 

 

 

3 1/4”x10” starting collar

 

3 1/4”x10” Vertical Discharge

1.Remove pre-mounted 6” transition adaptor or duct opening. Leave attached gasket in its original place.

2.Place rectangular transition adaptor as shown over gasket and by first installing 4 screws on half round section.

3.Mount the 3-1/4”x10” starting collar on top of transition piece with remaining screws.

Page 9
Image 9
Jenn-Air JXT9130CDP, JXT9136CDP specifications INSTALLATION7, Convertible Options, 4x10 Vertical Discharge