Installationstallation, cont’d

Installation Overview

Install an SW RGB or SW YUV A Series switcher as follows:

1

2

3

4

5

6

7

Turn off the input and output devices, and unplug their power cables.

If desired, mount the switcher in a rack, under furniture, or through furniture. See Mounting the Switcher below.

Connect the input and output devices to the switcher (see Cabling and Rear Panel Views on page 2-6).

If desired, connect a computer, RS-232 control system, or contact closure device to the Remote connector (see Remote connection on page 2-9).

Plug the switcher and, if appropriate, the input devices and output devices into a grounded AC source.

Turn on the input and output devices.

The image from each input device should appear on the output devices, and you should be able to switch from one input device to another. If this does not happen, double check steps 3 through 5 and make adjustments as needed.

Mounting the Switcher

Rack mounting the switcher

The SW2 switcher models are housed in half-rack width 1U high metal enclosures that can be rack mounted with an optional 1U Universal Rack Mount Kit or 1U Basic Rack Shelf (part #60-190-01or 60-604-01). The SW4 and SW6 switcher models are housed in rack-mountable, 1U high, 17" wide metal enclosures. The appropriate rack mount kit is included with the SW4 and SW6 switchers. Rack mount the switcher as follows:

SW2 models

1.

If rubber feet were installed on the bottom of the switcher, remove them.

2.

Place the switcher on one half of the optional 1U (one unit high, 19" wide)

 

rack shelf (part #60-190-01). Align the front of the switcher with the front of

 

the shelf, and align the threaded holes on the bottom of the switcher with the

 

holes in the rack shelf (figure 2-1).

3.

Secure the switcher to the rack shelf with the two provided 4-40 x 3/16"

 

machine screws. Insert the screws from the underside of the shelf, and

 

securely fasten them through diagonally opposite corners as shown in

 

figure 2-1.

4.

Fasten the false front panel (provided with the rack shelf) to the unoccupied

 

side of the rack (as shown in figure 2-1), or install a second half-rack-width

 

device in that side by repeating steps 1 through 3.

5.

Secure the rack shelf to the rack using four 10-32 x ¾" bolts. Insert the bolts

 

through #10 beveled washers, then through the holes in the rack ears.

SW4 and SW6 models

1.

If rubber feet were installed on the bottom of the switcher, remove them.

2.

Attach the rack mount brackets to the switcher with eight #8 machine screws,

 

provided (figure 2-2).

3.

Insert the switcher into the rack, align the holes in the mounting bracket with

 

those of the rack.

4.

Secure the switcher to the rack using the supplied machine screws.

2-2 SW RGB and YUV A Switchers • Installation

Page 12
Image 12
Extron electronic SW YUV A, SW RGB manual Installationstallation, cont’d, Installation Overview, Mounting the Switcher