Typical flexible connection.

 

A. Manifold entrance

 

B. Gas pressure regulator

 

C. Use pipe-joint compound.

A

D. Adapter (must have ½" male pipe

 

thread)

B

E. Flexible connector

F. Adapter

 

C

G. Use pipe-joint compound.

H. Manual gas shutoff valve

D

I. ½" or ¾" gas pipe

 

E

F

G

H

I

4.Install the pressure regulator with the arrow pointing up toward the bottom of the cooktop base and in a position where you can reach the regulator access cap.

B

A

C

D

A. Access cap

B. Rear of cooktop

C. Gas pressure regulator

D. Up arrow. Regulator must be installed with arrow pointing up to cooktop bottom.

IMPORTANT: All connections must be wrench-tightened. Do not make connections to the gas regulator too tight. Making the connections too tight may crack the regulator and cause a gas leak. Do not allow the regulator to turn on the pipe when tightening fittings.

Use only pipe-joint compound made for use with Natural and LP gas.

Do not use TEFLON® tape. You will need to determine the fittings required depending on your installation.

Complete Connection

1.Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.

A

B

A. Closed valve

B. Open valve

2.Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found.

3.Remove surface burner caps and grates from parts package. Align notches in burner caps with pins in burner base. Burner caps should be level when properly positioned. If burner caps are not properly positioned, surface burners will not light.

Place burner grates over burners and caps.

A

D

B

E

C

A. Burner cap

B. Burner ports

C. Burner base

D. Gas tube opening

E. Igniter head

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

4.Plug into a grounded 3 prong outlet.

11

Page 11
Image 11
Jenn-Air W10197058B installation instructions Typical flexible connection, Complete Connection