4.Remove the 2 screws that mount the motor mounting bracket to the vent box. Remove the blower motor and mounting bracket assembly from the vent box.
A
A
A. Blower motor mounting bracket screws (2)
5.Remove the 4 screws from the small cover plate on the rear of the vent chamber and set screws and cover plate aside.
6.Install blower motor and mounting bracket assembly to the bracket just below the downdraft tower motor. The blower exhaust opening should fit through the hole in the large cover plate on the opposite side of the vent chamber where the small cover plate was removed. Replace the 2 blower motor mounting bracket screws and tighten.
A
B
C
A. Downdraft tower motor
B. Large cover plate
C. Blower exhaust opening
7.Plug in the wire connector to the blower motor.
AB
A.Blower motor
B.Wire connector
8.Place the vent extension for the 6" diameter venting over the vent exhaust and screw into place using the 4 screws.
A
A
A. Vent extension screws (4)
9.Replace the vent box over the blower motor.
B
A
A. Blower motor
B. Vent box
11