Jenn-Air W10201609B Interior-mounted blower motor model, D E F B C G H A I, B D C A

Models: W10201609B

1 36
Download 36 pages 7.13 Kb
Page 5
Image 5
Interior-mounted blower motor model

Product Dimensions

Interior-mounted blower motor model

Top trim widths:

30¹⁄₄" (76.8 cm) for 30" (76.2 cm) vent 36¹⁄₄" (92.1 cm) for 36" (91.4 cm) vent

13¹⁄₂" (34.3 cm) retractable vent height

 

1¹⁄₂" (3.8 cm)

27" (68.6 cm) for 30" (76.2 cm) vent

³⁄₈" (0.95 cm)

33" (83.8 cm) for 36" (91.4 cm) vent

 

Terminal box cover

28³⁄₄"

(73.0 cm)

13" (33.0 cm)

D ³⁄₄" (1.9 cm)

13" (33.0 cm)

B 9¹⁄₄" (23.5 cm)

6" diameter

2¹⁄₈" (5.4 cm)

vent collar

 

Cabinet Dimensions

Interior-mounted blower motor model

7⁵⁄₈" (19.4 cm)

A= ¹⁄₂" (12.7 mm) minimum Manual background

23³⁄₄"

(60.3 cm)

21⁄₁₆"

21⁄₁₆"Manual background(54.1 cm)

(54.1 cm)

All cutouts are for 6" (15.2 cm) diameter vent system.

Locate power

Centerline of cooktop cutout

supply junction

 

box at lower

 

left hand

 

rear corner

 

of the cabinet.

 

NOTES:

See cooktop manufacturer’s instructions for cooktop cutout depth and width.

Use dimensions for vent system cutout location that applies to your installation.

Interior mounted blower systems connect with 6" (15.2 cm) round vent. The cutout locations for this vent system will depend on your specific installation.

Countertop Cutout Dimensions

IMPORTANT: Countertops with a bullnosed front edge are not recommended for these installations.

Some models require a countertop deeper than 25"

(63.5 cm); see the following Countertop Cutout Dimensions section.

To avoid mistakes, it is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts.

See Cooktop Installation Instructions for complete cutout dimensions, location dimensions and installation details.

D

E

Manual backgroundF

B C Manual background

Manual backgroundG

H

A Manual background

I

A. Downdraft vent

E. 1¹³⁄₁₆" (46.2 mm)

B. Cooktop

F. ½" (12.7 mm)

C. Measurement of cooktop rear

minimum

overhang.

G. ¼" (6.4 mm)

D. D = Measurement of cooktop

minimum

rear overhang (C) + 1¹³⁄₁₆"

H. Countertop and

[46.2 mm] (E)

backsplash

 

I. ½" (12.7 mm)

 

minimum

Countertop Cutout Dimensions

B

D

C

A

A. ½" (12.7 mm) minimum

C. 27¹⁄₂" (69.9 cm) on 30" (76.2 cm) models

to backsplash or rear

33¹⁄₂" (85.9 cm) on 36" (91.4 cm) models

wall

D. D = Measurement of cooktop rear

B. ³⁄₄" (19.1 mm) maximum

overhang + 1¹³⁄₁₆" (46.2 mm)

backsplash depth

 

5