Jenn-Air W10379137A manual Location Requirements, Opening Dimensions

Models: W10379137A

1 80
Download 80 pages 40.72 Kb
Page 9
Image 9
Location Requirements

Location Requirements

The water shutoff should be located in the base cabinet on

WARNINGeither side of the refrigerator or some other easily accessible area. If the water shutoff valve is not in the cabinets, the

plumbing for the water line can come through the floor. See “Water Supply Requirements” for more information.

Explosion Hazard

 

 

 

 

Keep flammable materials and vapors, such as

 

80" - 90"

 

 

gasoline, away from refrigerator.

 

(203-229 cm)

B

 

 

 

 

 

 

 

Failure to do so can result in death, explosion, or fire.

 

 

 

Dimension

 

 

 

 

IMPORTANT:

 

 

 

 

Observe all governing codes and ordinances.

 

 

 

 

It is recommended that you do not install the refrigerator near

 

84" (213.4 cm)

 

 

an oven, radiator, or other heat source.

 

to bottom of solid soffit

 

Do not install in a location where the temperature will fall

 

 

 

 

below 55°F (13°C).

 

 

 

 

Floor must support the refrigerator weight, more than 600 lbs

 

 

 

 

(272 kg), door panels and contents of the refrigerator.

 

 

 

77"

 

 

 

 

Ceiling height must allow for side tipping radius. See “Tipping

 

 

 

(196 cm)

Radius.”

 

 

 

 

Location should permit door to open fully. See “Door Swing

 

 

A

 

Dimensions.”

 

 

 

Location must permit top grille removal. See “Opening

 

 

Width

 

 

(see chart following)

Dimensions.”

 

 

 

 

Opening Dimensions

 

 

 

 

The width of the opening, from side to side, must be as

 

 

 

 

specified for your model, for at least 2" (5.08 cm) back from

 

 

 

 

the face of the cabinet.

 

 

 

 

NOTE: If your opening does not meet this requirement, you

 

 

 

 

will need to make modifications.

 

 

 

 

A solid soffit or wall cabinet must be installed 84" (213.4 cm)

 

 

 

 

above the floor. If the solid soffit is higher than 84" (213.4 cm)

 

C

1"

 

or one is not available, then the refrigerator must be braced.

 

6"

(2.54 cm)

6"

If the anti-tip boards are needed, they must be attached to the

 

(15.2 cm)

 

(15.2 cm)

 

 

 

 

rear wall studs so that there is 84" (213.4 cm) from the bottom

 

 

 

 

of the anti-tip board to the floor. See “Install Anti-Tip Boards”

 

 

 

 

for more information.

Model

Width A

 

Dimension B

For a fully integrated installation, a minimum of 6" (15.24 cm)

 

(as shown above)

 

(as shown above)

of open space above the refrigerator is required. See “Fully

36

36" (91.4 cm)

 

4" (10.2 cm)

Integrated Installation.” Anti-tip boards are required. See

 

42

42" (106.7 cm)

 

10" (25.4 cm)

“Install Anti-Tip Boards” for more information.

 

 

 

 

 

A grounded 3 prong electrical outlet should be located within

 

 

 

 

a specified number of inches from the right-hand side

Installation Type

Depth C (as shown above)

cabinets or end panel. See the chart following the graphic for

Standard Flush

25" (63.5 cm) minimum

the number of inches required for your model. For more

information, see “Electrical Requirements.”

(new installation)

 

 

 

Retrofit Installations

24" (60.9 cm) minimum

 

IMPORTANT:

 

 

 

The width of the opening (Width A), must be as specified

 

for your model, for at least 2" (5.08 cm) back from the face

 

of the cabinet.

 

 

 

NOTE: If your opening does not meet this requirement,

 

you will need to make modifications.

 

Flooring under refrigerator must be at same level as the

 

room. Face of cabinetry must be plumb.

9

Page 9
Image 9
Jenn-Air W10379137A manual Location Requirements, Opening Dimensions