Adjustments
Unplug the machine from the power source before making any repairs or adjustments. Failure to comply may cause serious injury.
Tilting the Table
Referring to Figure 7:
1.Loosen the lock knob (A).
2.Tilt table (C) up to 50 degrees maximum to the right or down 5 degrees to the left. The angle can be read on the scale (B) on the trunnion bracket.
Note: Table perpendicular (90º) to the blade corresponds to a scale indication of 0º.
3.Tighten the lock knob (A).
Note: The table stop (E) must be adjusted to permit the table to tilt to the left.
90º Table Stop Adjustment
Adjusting the table stop
The table stop (E, Fig. 7) is typically set to stop the table at 90º (perpendicular) with the blade.
1.Disconnect machine from power source.
2.Loosen lock knob (A, Fig. 7); then tilt the table (C, Fig. 7) down, bringing it to rest against the table stop (E, Fig. 7).
3.Use a square (J, Fig. 8) placed on the table (C, Fig. 8) and against the blade (H, Fig. 8) to see if the table is 90º to the blade.
4.If an adjustment is necessary, tilt the table up to access the table stop (E, Fig. 7).
5.Loosen the jam nut (D, Fig. 7) and turn the table stop (E, Fig. 7) in or out to raise or lower the stop. Tighten the jam nut to hold the table stop in place.
6.Tilt the table back to level, letting it rest against the stop and confirm table is 90º with the blade as described in step 3.
For left tilt down to 5º, the table stop (E, Fig. 7) must be adjusted further.
Adjusting the table tilt indicator
1.Set the table at 90º with the blade.
2.Confirm that the table tilt indicator (F, Fig. 8) points to zero.
If adjustment is required:
3.Slightly loosen screw securing indicator, adjust indicator to point to zero; then
Figure 7
Figure 8
Figure 9
10