FORTRAFORCE4G15 & G15+ RAID System InstallationGuide Rev A 2-1
This chapter covers specification information for all FORTRA
FFoorrccee44
G15
Tower and G15+ Rackmount or Tower enclosures.
Environmental Specifications
Operating Temperature: 5°C to 40°C (41°F to 104°F)
Storage Temperature: 0°C to 65°C (32°F to 149°F)
The maximum recommended ambient temperature depends on the
recommendation of the manufacturer for the devices being installed.
Electrical Specifications
AC Inlet Type: IEC320/EN60320
Power Cord: NEMA5-15P
Power Supply: Auto-switching for 110/220V operation
Agency Compliance
FORTRA
FFoorrccee44
G15 and G15+ enclosures have been designed and built to
comply with the FCC Class A, UL, CSA/TUV, CE, and C-Tick standards. For
more information on FCC Class A compliances, see page 2.
Packaging Specifications
FORTRA
FFoorrccee44
G15 and G15+ packaging has been designed to be reusable
and recyclable. Drives may be installed and shipped in the canisters as long as
the canisters are not installed in the enclosure. Shipping the unit with canisters
and/or power supplies installed in the enclosure may cause damage to the
enclosure or to the drives and will void the warranty.
Packaging complies with ISTA (International Safe Transit Association) standards
and has been ISTA certified.
Each canister is pre-packaged in an anti-static bag. Do not throw the packaging
away if the product is intended for re-shipping. When transporting or shipping a
JMR approved shipping container must be used.
SAFETY TIP: Reshipping the enclosure with canisters, drives, or power
supplies installed in the enclosure may cause damage to these
components and will void the warranty
SICHERHEITSHINWEIS: Der Versand des Gehäuses mit eingebauten
Einschüben, Platten und Netzteilen kann zur Beschädigung dieser
Komponenten führen und somit den Garantieanspruch gefährden.