John Lewis JLDWS1202 instruction manual Notes for Test Institutes, Sample loading arrangements

Models: JLDWS1202

1 40
Download 40 pages 36.25 Kb
Page 30
Image 30
Notes for Test Institutes

Notes for Test Institutes

Testing in accordance with EN 60704 must be carried out with the appliance fully loaded and using the test cycle (see “Cycle Table”). Tests in accordance with EN 50242 must be carried out when the salt dispenser in the water softener and the rinse aid dispenser have been filled with salt and rinse aid respectively, and using the test cycle (see “Cycle Table”).

 

Full load:

Half load:

 

12 place settings

6 place settings including

 

including serving

serving dishes, leaving alter-

 

dishes

nate positions in the rack free

Amount of detergent required:

5g + 25g (Type B)

20g (Type B)

 

 

 

Rinse aid setting:

4 (Type III)

4 (Type III)

 

 

 

Sample loading arrangements:

Upper basket *)

*) If necessary, move the cup rack from right to left. When doing this, ensure that the cup rack is at the same height.